Technical Data

Category
Maximum Fluid Working
Pressure
Maximum Input Pressure to
Motor
Pressure Ratio
Fluid:Air
Fluid:Oil
Air Inlet
Recommended Air Supply
Hose Size
Air Consumption
Hydraulic Supply Inlet
Hydraulic Return Outlet
Recommended Hydraulic
Hose Size
Maximum Hydraulic Oil Flow Models H-50 and H-XP3: 10 gpm (3.8 lpm), 50 cycles/min
Hydraulic Oil Consumption
56
Data
Model A-25: 1920 psi (13 MPa, 130 bar)
Models A-50 and H-50: 2000 psi (14 MPa, 140 bar)
Models A-XP2 and H-XP3: 3000 psi (20.7 MPa, 207 bar)
Models A-25 and A-XP2: 120 psi (0.82 MPa, 8.2 bar) air
Model A-50: 75 psi (0.5 MPa, 5 bar) air
Models H-50 and H-XP3: 1200 psi (8.4 MPa, 84 bar) oil
Model A-25: 16:1
Model A-XP2: 25:1
Model A-50: 26:1
Model H-50: 1.65:1
Model H-XP3: 2.76:1
Models A-25 and A-XP2: 1/2 npsm(f)
Model A-50: 3/4 npsm(f)
Models A-25 and A-XP2: 1/2 in. (13 mm) ID minimum
Model A-50: 3/4 in. (19 mm) ID minimum
Model A-25: 40 scfm at 120 psi (0.82 MPa, 8.2 bar), 1.6 gpm (6.1 lpm)
Model A-XP2: 40 scfm at 120 psi (0.82 MPa, 8.2 bar), 1.0 gpm (3.8 lpm)
Model A-50: 80 scfm at 75 psi (0.5 MPa, 5 bar), 5.0 gpm (19 lpm);
35 scfm at 75 psi (0.5 MPa, 5 bar), 2.0 gpm (7.6 lpm)
Models H-50 and H-XP3: 3/4 npt(f)
Models H-50 and H-XP3: 1 in. npt(f)
Supply Hose: 3/4 in. (19 mm) ID minimum
Return Hose: 1 in. (25 mm) ID minimum
Models H-50 and H-XP3: 1.0 gpm (38 lpm) per 5 cycles
Technical Data
309813B

Advertisement

Table of Contents
loading

Table of Contents