Connect Electrical Cord - Graco E Series Operation

Electric, heated, plural component proportioner
Table of Contents

Advertisement

3.

Connect electrical cord

Power cord is not supplied. See T
Table 2: Power Cord Requirements
Part No.
Model
246024
E-XP1
246025
E-20
246026
E-30
246028
E-XP2
246029
E-XP1
246030
E-20
246031
E-30
246032
E-XP2
246033
E-XP1
246034
E-20
246035
E-30
246036
E-XP2
WARNING
Read warnings, page 5.
a.
230V, 1 phase: Using 5/32 or 4 mm hex
allen wrench, connect two power leads
to L1 and L2. Connect green to ground
(GND).
L1
L2
309551C
2.
ABLE
Cord Specification
2
AWG (mm
)
6 (13.3), 2 wire + ground
8 (8.4), 2 wire + ground
6 (13.3), 2 wire + ground
4 (21.2), 2 wire + ground
10 (5.3), 4 wire + ground
10 (5.3), 4 wire + ground
10 (5.3), 4 wire + ground
10 (5.3), 4 wire + ground
8 (8.4), 3 wire + ground
10 (5.3), 3 wire + ground
8 (8.4), 3 wire + ground
6 (13.3), 3 wire + ground
GND
TI2515A
b.
230V, 3 phase: Using 5/32 or 4 mm hex
allen wrench, connect three power
leads to L1, L2, and L3. Connect green
to ground (GND).
GND
L1
L2
L3
c.
380V, 3 phase: Using 5/32 or 4 mm hex
allen wrench, connect three power
leads to L1, L2, and L3. Connect neutral
to N. Connect green to ground (GND).
GND
L1
L3
L2
N
Setup
TI3248A
TI2725A
17