Graco E Series Operation page 33

Electric, heated, plural component proportioner
Table of Contents

Advertisement

Circulation Through Gun
Manifold
WARNING
Read warnings, page 5. Do not circulate fluid contain-
ing a blowing agent without consulting with your mate-
rial supplier regarding fluid temperature limits.
Circulating fluid through the gun manifold allows rapid
preheating of hose.
1.
Install gun fluid manifold (P) on Part No. 246362
accessory circulation kit (W).
P
W
309551C
R
TI2767A
2.
Connect high pressure circulation lines (R) to
circulation manifold. Route circulation lines back
to respective component A or B supply drum.
Use hoses rated at the maximum working pres-
sure of this equipment.
3.
Follow Load fluid with feed pumps, page 25.
4.
Turn main power ON
5.
Set temperature targets, see page 26. Turn on
A
B
,
, and
ing
.
6.
Press
to display actual temperatures.
7.
Circulate fluid only in jog mode (see page 34)
until temperatures reach targets.
Fluid Circulation
.
heat zones by press-
33