Startup; Load Fluid With Feed Pumps - Graco E Series Operation

Electric, heated, plural component proportioner
Table of Contents

Advertisement

Startup

WARNING
Do not operate Reactor without all covers and shrouds
in place.
1.
Load fluid with feed
pumps
The Reactor is tested with oil at the factory. Flush
out the oil with a compatible solvent before spray-
ing. See page 36.
a.
Check that Setup steps 1-13 are com-
plete, pages 16-24.
b.
Turn on component B agitator, if used.
c.
Turn both PRESSURE RELIEF/SPRAY
valves (SA, SB) to SPRAY.
309551C
SA
SB
TI2482A
d.
Open fluid inlet valves (FV).
e.
Start feed pumps.
WARNING
Always provide two grounded waste containers to
keep component A and component B fluids separate.
f.
Hold gun fluid manifold over two
grounded waste containers. Open fluid
valves A and B until clean, air-free fluid
comes from valves. Close valves.
Startup
FV
TI2501A
TI2484A