h.
Manual current control mode only:
WARNING
Read warnings, page 5. When in manual current con-
trol mode, monitor hose temperature with thermome-
ter. Install per instructions below. Thermometer
reading must not exceed 160°F (71°C).
If FTS is disconnected or display shows
diagnostic code E04, turn main power
switch OFF
to clear diagnostic code and enter man-
ual current control mode.
will show current to hose. Current is not
limited by target temperature.
To prevent overheating, install hose
thermometer close to gun end, within
operator view. Insert thermometer
through foam cover of A component
hose so stem is next to inner tube.
Thermometer reading will be about
20°F less than actual fluid temperature.
If thermometer reading exceeds 160°F
(71°C), reduce current with
309551C
3.
then ON
display
key.

Set pressure

a.
Press
b.
Press motor
start. Display shows system pressure.
Motor runs until setpoint reached.
c.
Press
shows desired fluid pressure. Display
will show setpoint for 10 sec, then
change to actual pressure.
If display pressure is greater than setpoint pres-
sure, trigger gun to reduce pressure.
If display shows J xx, unit is in jog mode. To exit
jog mode, see page 34.
d.
To display cycle count, press
To clear counter, press and hold
e.
PSI
Press
sure scale.
Startup
.
. Motor and pumps
or
until display
.
for 3 sec.
BAR
or
to change pres-
27