Pin No.
1
2
3
4
5
6
7
8
Hood
Note 1. Connect the cable shield to the connector hood at both ends of the cable.
Note 2. There are two connection methods for Ethernet: T568A and T568B. The T568A connection method is
shown above, but the T568B connection method can also be used.
Connector Specifications
Item
Electrical characteristics Conforms to IEEE 802.3 standards.
Connector structure
Pin Assignments
Physical layer standards: 100BASE-TX
8
1
Pin No.
1
Transmission data +
2
Transmission data -
3
Reception data +
4
5
6
Reception data -
7
8
Physical layer standards: 1000BASE-T
8
1
Pin No.
1
Communication data DA+
2
Communication data DA-
3
Communication data DB+
CK3E-series Programmable Multi-Axis Controller User's Manual Hardware (I610)
Wire color
White-Green
Green
White-Orange
Blue
White-Blue
Orange
White-Brown
Brown
Shield
RJ45 8-pin modular connector (Conforms to ISO 8877)
Signal name
Abbreviation Signal direction
TD+
TD−
RD+
Not used.
---
Not used.
---
RD -
Not used.
---
Not used.
---
Signal name
Abbreviation Signal direction
BI_DA+
BI_DA-
BI_DB+
Wire color
White-Green
Green
White-Orange
Blue
White-Blue
Orange
White-Brown
Brown
Shield
Specification
Output
Output
Input
---
---
Input
---
---
Input/output
Input/output
Input/output
4 Mounting and Wiring
Pin No.
1
2
3
4
5
6
7
8
Hood
4-19
4