Omron CK3E Series Hardware User Manual page 53

Programmable multi-axis controller
Hide thumbs Also See for CK3E Series:
Table of Contents

Advertisement

3
Establish an SSH connection, and execute the sync command from the terminal that you con-
nected to.
4
Wait for at least 5 seconds and turn OFF the power supply.
 Procedure to Download to the Built-in Flash Memory (Version 2.5 or Later)
For PMAC firmware revision version 2.5 or later, you can also use the following procedure to store
the user program into the built-in flash memory.
1
Download the user program from the Power PMAC IDE.
2
At the Power PMAC IDE terminal, enter Sys.SyncSave=1.
3
At the Power PMAC IDE terminal, execute the save command.
Wait until the save completed notification is displayed on the Power PMAC IDE.
4
At the Power PMAC IDE terminal, enter Sys.SyncSave=0.
5
Wait for at least 5 seconds and turn OFF the power supply.
CK3E-series Programmable Multi-Axis Controller User's Manual Hardware (I610)
4 Mounting and Wiring
4-3
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ck3e-1210Ck3e-1310Ck3e-1410

Table of Contents