Empire Comfort Systems Boulevard MULTIFUNCTION REMOTE DVLL60BP90N-2 Installation Instructions Manual page 22

Direct vent zero clearance gas fireplace heater
Hide thumbs Also See for Boulevard MULTIFUNCTION REMOTE DVLL60BP90N-2:
Table of Contents

Advertisement

Finishing Methods
FINISHED WALL
(COMBUSTIBLE)
NON-COMBUSTIBLE
BOARD
FINISHED WALL
(COMBUSTIBLE)
NON-COMBUSTIBLE
BOARD
NON - COMBUSTIBLE
BOARD OVER
FIREPLACE FACE
(NOT SUPPLIED)
Page 22
INSTALLATION (CONT'D)
2" X 4" HEADER
TOP FRAMING
LEDGE
Figure 30
2" X 4" HEADER
TOP FRAMING
LEDGE
Figure 31
NON - COMBUSTIBLE
BOARD FLUSH TO
FIREPLACE FACE (SUPPLIED)
Figure 32
Attention: Cold climate installation recommendation: When
installing this fireplace against a non-insulated exterior wall, it
is recommended that the outer walls be insulated to conform to
applicable insulation codes.
Vent Runs
In planning the installation for the fireplace, it is necessary to
install certain components before the fireplace is completely
positioned and installed. These include the direct vent system,
gas piping and electrical wiring.
The fireplace can be mounted on any of the following surfaces:
1. A flat, hard combustible or non-combustible surface.
2.
A raised wooden platform.
VERTICAL, 90-DEGREE ELBOW WITH HORIZONTAL
TERMINATION
12" MINIMUM
(305mm)
VERTICAL VENT
REQUIRED
MAXIMUM HORIZONTAL
RUN WITH MINIMUM
VERTICAL RISE AND
90° ELBOW
Finishing Options
Non-Combustible board installed over the fireplace face
(framing bracket flush). See Figure 29.
Non-Combustible board installed flush to face (framing
brackets at 1/2-inch set back). See Figure 30.
Figure 31 shows both finishing options.
Use Non-Combustible materials where indicated for the
fireplace installation. Non-combustible materials do not
ignite or burn as a result of using the fireplace. These
include metal, brick, ceramic, concrete, slate, glass and
plaster. Adhesives must be rated for high temperatures. Any
mechanical fasteners used to install material must also be
non-combustible, including wall anchors and tile spacers.
Materials that pass the ASTM E 136 test (Standard Test
Method for Behavior of Materials in a Vertical Tube Furnace
at 750C) are considered non-combustible.
2'
(610mm)
Figure 33
41117-0-0819

Advertisement

Table of Contents
loading

Table of Contents