Determining the Faulty SIMM Pair

The address given by the System Responder Address
is contiguous, even though empty slots are permitted.
Memory boards are installed in pairs of the same
memory capacity. The operating system starts map-
ping memory at Pair 3, if it exists. In other words, it
maps starting with the highest numbered pair through
to the Pair 0. To determine the faulty pair of SIMMs,
perform the following steps.
1 Using Table 10, determine the HEX value address range
Table 10

Memory Address Ranges

Pair
(3 thru 0)
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
_________
Dealing with HPMC (Uncorrectable Error)
for each SIMM pair in the system.
Memory
Size (MB)
0-8
8-16
16-24
24-32
32-40
40-48
48-56
56-64
64-72
72-80
80-88
88-96
96-104
Troubleshooting
Address Range
0x00000000 - 0x007FFFFF
0x00800000 - 0x00FFFFFF
0x01000000 - 0x017FFFFF
0x01800000 - 0x01FFFFFF
0x02000000 - 0x027FFFFF
0x02800000 - 0x02FFFFFF
0x03000000 - 0x037FFFFF
0x38000000 - 0x03FFFFFF
0x04000000 - 0x047FFFFF
0,048000000 - 0x04FFFFF
0x05000000 - 0x057FFFFF
0x05800000 - 0x05FFFFFF
0x06000000 - 0x067FFFFF