Step
8
Unfasten the 2 hooks
and remove the service
monitor PCB.
2. Remove the inverter PCB
(MID2).
Remove the 7 screws
1
and remove the inverter
PCB (MID2).
Removal Procedure
Procedure
LED A
LED 1
LED 2
LED 3
LED 4
Operation mode switch
(SW2)
Hook
FU201 (3.15A)
Hook
Priority room setting switch
(SW4)
Wiring error check switch
(SW3)
Forced operation [ON/OFF]
switch (SW1)
NIGHT QUIET mode setting
switch (SW5)
(R17348)
Inverter PCB
(MID2)
(R10355)
Removal of PCBs