This code is sent when the 128 event internal buffer has
reached a level of 75% full since the last successful upload
from a downloading computer.
I___I___I
DLS Lead IN
This code is sent after the panel has been successfully called
by DLS, but before the panel calls DLS back via the Down-
loading Telephone Number when Callback is enabled. This
code is also sent when 'User Initiated Call-up' is initiated.
I___I___I
DLS Lead OUT
This code is sent by the panel when DLS has completed a suc-
cessful DLS call to the panel.
I___I___I
General Zone Trouble Alarm
This reporting code is sent when a zone enters the 'Fault'
state. This is the 'short' state on DEOL hardwired zones and/
or a loss of supervisory on a wireless zone.
I___I___I
General Zone Trouble Restore
I___I___I
Delinquency Reporting Code
This code is sent when the programmed interval (section
[370] [7]) and time of day (section [371]) have elapsed.

[352] Test Transmission Reporting Codes

These codes are sent to the System Test Transmission Call Direction
Group programmed in section [368].
I___I___I
Periodic Test Transmission
This code is sent when the programmed interval (section
[370] [7]) and time of day (section [370]) have elapsed.
I___I___I
System Test
This code is sent to test the communicator when the
[*][6][Master Code][4] command is used to perform a man-
ual system test.
I___I___I
Future Use

[353] Wireless Maintenance Reporting Codes

These codes are sent to the System Maintenance Alarms and Resto-
rals Call Direction Group programmed in section [367].
I___I___I
General Zone Low Battery Alarm
This code is sent to report a Low Battery condition on the sys-
tem's wireless devices. Individual zones are not described
using the pulse formats, but the individual zones will be
logged to the event buffer. SIA and Contact I.D. formats will
identify the zone with the condition.
I___I___I
General Zone Low Battery Restore
[360] Communicator Format Options
firealarmresources.com
[352] Test Transmission Reporting Codes
01
20 bps, 1400 Hz Handshake
02
20 bps, 2300 Hz Handshake
03
DTMF Contact I.D. - The Account Codes must be 4 decimal
digits in length; all reporting codes must be 2 digits in length.
This format uses DTMF tones as the communication medium.
It requires a dual-tone initial handshake (1400/2300) and
after sending the message, it requires a 1400 Hz kissoff.
This software has a built in Automatic Contact I.D. reporting
code table similar to SIA. This table may be found in its
entirety in Appendix A. An option exists that determines
whether or not the Contact I.D. format will transmit Auto-
matic or Programmed reporting codes (see section [381]
option 7).
If programmed Contact I.D. reporting codes are used and if
'01-FE' is entered in the associated progamming section then
the programmed codes will be sent in the ADEMCO protocol.
If '00' or 'FF' has been entered into the associated section, no
code will be transmitted.
If Auto-contact I.D. reporting codes (See App. A) are used
and if '01-FF' is entered in the associated progamming sec-
tion then the programmed codes will be sent in the ADEMCO
protocol. If '00' has been entered into the associated section,
no code will be transmitted.
04
SIA FSK - See section [381] option [3]. See Appendix A
for a complete list of pre-programmed reporting codes
This format uses 300 Baud FSK as the communication
medium. Account codes must be 4 hexadecimal digits in
length and reporting codes must be 2 digits in length. The
SIA format will transmit a 4 digit account code, a 2 digit iden-
tifier code and a 2 digit reporting code. The 2 digit identifier
is pre-programmed in the panel.
Reporting Codes
If programmed SIA reporting codes are used and if '01-FE' is
entered in the associated progamming section then the pro-
grammed codes will be sent. If '00' or 'FF' has been entered
into the associated section, no code will be transmitted.
If Auto-SIA reporting codes (See App. A) are used and if '01-
FF' is entered in the associated progamming section then the
programmed codes will be sent. If '00' has been entered into
the associated section, no code will be transmitted.
Level 2 (Hardcoded)
The SIA communication format used in this product follows
the Level 2 specifications of the latest SIA Digital Communi-
cation Standard – July 1997 (Draft Only).
05
Pager - Pager format uses Sur-Gard 4/3 DTMF timing param-
eters. It sends the account code, reporting code and a [#]
(hex C) 1 time only. There is no checksum, parity or hand-
shake. This communication format cannot be used for
backup or alternate dialing (Phone Number 3). Communica-
tion of this format does not generate or clear any FTC condi-
tions.
If an automatic communications format is used for any other
phone number, the desired reporting code to be transmitted
via pager must be programmed for the event!