10.4

Exposure Time

This parameter sets variable exposure time.
The control method is selectable from
Manual exposure control, which uses preset exposure time.
Auto exposure control, which is maintain exposure time with brightness of target.
GenICam Parameters
ExposureMode
ExposureTime
[ExposureTime
Selector]
ExposureAuto
(*1) The approximate value of set value, sets to camera and display it.
(*2) Please sets range of auto exposure control with "Exposure Auto Limit Min" and "Exposure Auto Limit Max" when
using auto exposure control.
10.5

Black Level

This parameter sets the black level (clamp level for black signal).
Sets the black level at "Black Level".
The lower limit of signal is clamped at this setting level. The signal does not lower than this.
GenICam Parameters
BlackLevel
STC-MBS202POE-BPF
Product Specifications and User's Guide
IEnumeration Type
Exposure control selection
Selection: "Off" and "Timed"
Off: Exposure time is "1 / Frame rate"
Timed: Exposure time is "Exposure Time"
IFloat Type
Exposure time (in μsecond) (*1)
Range: 1.000000 to 16,777,215.000000
Default: 18,166.000000
IEnumeration Type
Auto exposure ON / OFF selection (*2)
IFloat Type
Black Level
Range:
12bits output: 0 to 240
10bits output: 0 to 60
8bits output: 0 to 15
Default: 0