Keypad Functions; General Information; Arming Functions - ADEMCO VISTA-10SE Installation Instructions Manual

Hide thumbs Also See for VISTA-10SE:
Table of Contents

Advertisement

Keypad Functions

Information

Arming Functions

www.PDF-Zoo.com
General
Note that if you enabled QUICK ARM (field 21), the [#] key can be pressed
instead of entering the security code, for any of the arming procedures (Away,
Stay, Instant, Maximum, etc.). The security code is always required, however,
when disarming the system.
NOTE: The "Quick Arm" feature will function only if the Master Code has been
programmed (see Assigning the Master Code on the previous page).
The keypad allows the user to arm and disarm the system, and perform other
system functions, such as bypassing zones, and display zone descriptors.
Zone and system conditions (alarm, trouble, bypass) are displayed in the
Display Window.
When an alarm occurs, keypad sounding and external sounding will occur, and
the zone(s) in alarm will be displayed on the keypad. Pressing any key will
silence the keypad sounder for 10 seconds. Disarming the system will silence
both keypad and external sounders. When the system is disarmed, any zones
that were in an alarm condition during the armed period will be displayed
(memory of alarm). To clear this display, simply repeat the disarm sequence
(enter the security code and press the OFF key) again.
The keypads also feature chime annunciation, and 3 panic key pairs, or
individual panic keys (depending on keypad type – see Panic Keys on next
page), for silent, audible, fire or personal emergency alarms. These keys can
notify the central station of an alarm condition, if that service is connected.
The following is a brief list of system commands. For detailed information
concerning system functions, refer to the User's Manual.
Disarmed, Not Ready ........... Before arming, the system must be in the
Arming Away ........................ Enter code + AWAY [2].
Arming Stay .......................... Enter code + STAY [3].
Arming Instant ...................... Enter code + INSTANT [7].
Arming Maximum ................. Enter code + MAXIMUM [4].
Quick Arming ....................... Simply press [#] key in place of code, then press
(if enabled) ......................... AWAY, STAY, INSTANT, or MAXIMUM to arm
Disarming ............................. Enter code + OFF [1].
Bypassing Zones ................. Enter code + BYPASS [6] + zone number(s).
Forced (Quick) Bypass ........ To automatically bypass all faulted zones, use
(if enabled) ........................ the "Quick Bypass" method:
Chime Mode .......................... Enter code + CHIME [9].
Arming
Mode
AWAY
STAY
INSTANT
MAXIMUM
firealarmresources.com
READY condition (all zones must be intact). If
the "NOT READY" message appears, press the
READY [ ] key to display faulted zones.
system as desired. Note that the [#] key cannot
be used in place of code when disarming the
system.
Enter code + BYPASS, then wait for all open
zones to be displayed. Arm when display
indicates "Bypass" and "Ready to Arm".
To turn chime off, enter code + CHIME again.
SUMMARY OF ARMING MODES
Features for Each Arming Mode
Exit
Entry
Delay
Delay
Yes
Yes
Yes
Yes
Yes
No
Yes
No
– 74 –
Perimeter
Interior
Armed
Armed
Yes
Yes
Yes
No
Yes
No
Yes
Yes