System Operation; Security Codes; Installer Code; Assigning The Master Code - ADEMCO VISTA-10SE Installation Instructions Manual

Hide thumbs Also See for VISTA-10SE:
Table of Contents

Advertisement

Security Codes

Installer Code

Assigning the
Master Code
Changing the
Master Code

User Codes

Important: This code is
useful only when the
system is connected to a
central station.
www.PDF-Zoo.com
Section 16. SYSTEM OPERATION
The installer programs the 4-digit Installer Code initially as part of the
programming procedure. The factory default Installer code is "4-1-1-1", but
may be changed in field 20. Note: The Installer Code is defined as User #1.
The Installer code is the only code that can allow re-entry into programming
mode. In normal operation mode, only the Master code can be used to enter
the User codes (refer to Assigning the Master Code ).
See MECHANICS OF PROGRAMMING section in the PROGRAMMING
GUIDE manual for details on exiting the programming mode via 98 or 99.
In normal operation mode, assign the 4-digit Master Code as follows:
Installer Code + 8 + 2 + 4-digit Master Code
Note: The Master Code is defined as User #2.
In normal operation mode, the Master code can be changed by entering:
Master Code + 8 + 2 + New Master Code + New Master Code again
In normal operation mode, the Master security code can be used to assign up
to 4 secondary 4-digit security codes. It can also be used to remove sec-
ondary codes from the system (individually).
To assign (or change) a Secondary security code, enter (via keypad) :
Master Code + [CODE key] + User # (3–6) + desired 4-digit Secondary Code
The system will emit a single beep when each secondary code has been suc-
cessfully entered.
To delete a Secondary security code, enter (via keypad) :
Master Code + [CODE key] + User # (3–6)
Notes:
• All Master and Secondary security codes permit access to the system for
arming, disarming, etc.
• If a secondary code is inadvertently repeated for different users, the lower
user number will take priority.
• Opening and closing reports are sent for the Master code as No. 02, with
the appropriate subscriber number. Secondary user codes are sent as Nos.
3 through 6 respectively, with the appropriate subscriber number.

Duress Code

This feature is intended for use when you are forced to disarm or arm the
system under threat. When used, the system will act normally, but can silently
notify the central station of your situation, if that service has been provided.
The Duress code may be any 4-digit code assigned to User Number 8.
To program a Duress code:
1. Enter Master Code.
2. Press the CODE [8] key.
3. Press the [8] key again (8 = Duress code User No.).
4. Enter the desired 4-digit Duress Code. The keypad will beep once.
Note:
To change the Duress code:
Repeat steps 1, 2, and 3, and then step 4 with the new Duress Code.
To delete the Duress code:
Perform steps 1, 2, and 3, and then stop. When the keypad beeps once it
signifies that the code has been deleted.
firealarmresources.com
The Duress code must differ from the Master Code or any other
User's Code.