7. The system will search for the next zone that does not have a serial
number associated with it. If one is found, the prompt in step 5, along
with the appropriate zone number, will be displayed. Follow steps 5
and 6 for the remaining wireless zones.
8. After all wireless zones have been displayed, whether enrolled or not,
the "Enter Zn Num." prompt will appear.
1 5
Enter "00" to exit the serial number Sequential mode and return to the
data field programming mode.
When you have finished programming all zones, test each using the
system's TEST mode (see TESTING THE SYSTEM section).
Do not use the Transmitter ID Sniffer mode for testing, as it will only
check for transmission of one zone on a particular transmitter, and
NOT the zones assigned to each additional loop.