Philips 3007 Series Service Manual page 21

Chassis tpm9.2he la
Table of Contents

Advertisement

Item Item value
8
NVM COPY TV to USB
9
NVM COPY USB to TV
10
RESET_PBS_PWD
11
DIM_LIB_RESET
12
SRC_METER RESET
13
CIPLUS_QUERY
14
CIPLUS UPDATE
15
EDID UPDATE
16
Test Pattern
17
VIRGIN_MODE
18
E-Fuse
18
ORT_MODE
20
VGA_UART_SWITCH
21
AGEING MODE
22
CLR_TEMP_R
23
CLR_TEMP_G
24
CLR_TEMP_B
25
AUTO_COLOR
26
ADC_GAIN_R
27
ADC_GAIN_G
28
ADC_GAIN_B
29
ADC_OFFSET_R
30
ADC_OFFSET_G
31
ADC_OFFSET_B
32
YPBPR_PHASE
33
AUD_LIMITER_MODE
34
AUD_THRESHOLD_BYTE1
35
AUD_THRESHOLD_BYTE2
36
AUD_THRESHOLD_BYTE3
37
AUD_GAIN_LINEIN
38
AUD_GAIN_HDMI
39
AUD_GAIN_ATV
40
AUD_GAIN_DTV
41
AUD_GAIN_USB
42
AQ_INDEX
43
Audio Test Mode
44
Audio Channel Type
45
DUMP PQ FROM TV
46
LOAD PQ to TV
47
DUMP AQ FROM TV
48
LOAD AQ to TV
49
FEF CHECK
50
EXIT_FACTORY
How to Exit the Factory mode
Use one of the following methods:
Select EXIT_FACTORY from the menu and press the "OK"
button.
Note: When the TV is switched "off" by a power interrupt, or
normal switch to "stand-by" while in the factory mode, the TV
will show up in "normal operation mode" as soon as the power
is supplied again. The error buffer will not be cleared.
5.2.5
Contents of the Factory mode (for series HFL3117D/10) :
Purpose
To perform extended alignments.
Specifications
Displaying and or changing Panel ID information.
Displaying and or changing Tuner ID information.
Error buffer clearing.
Various software alignment settings.
Testpattern displaying.
Public Broadcasting Service password Reset.
Service Modes, Error Codes, and Fault Finding
Default value
32"
42"
Description
Press OK
Use this to store the NVM data to the REPAIR folder of a FAT formatted USB memory stick. The TV will write two files
in the REPAIR folder of the memory stick. It will create this folder if it does not exist. The items are "Channel list",
"Personal settings", "Option codes", "Display-related alignments" and "History list". In case the download to the USB
stick was not successful "Failure" will appear. In this case, check if the USB stick is connected properly. Now the
settings are stored onto the USB stick and can be used to download onto another TV or other SSB. Uploading is of
course only possible if the software is running and if a picture is available. This method is created to be able to save
the customer's TV settings and to store them into another SSB.
Press OK
Use this to store the NVM data from the USB memory stick to the TV. The TV will save the two files which were created
in item 8 to the NVM of the set. Use these options when replacing a SSB. When "USB to TV Success" is displayed
remove the power and restart the TV
Press OK
Use this to reset the Child Lock
Press OK
Reset the Dimming
Press OK
Reset the Source meter
Press OK
Shows the Validity of the CI+ key and the supplier information
Press OK
Used to enter a new CI+ code into the NVM. This can only be used when no CI+ code exists in the NVM
Press OK
Used to enter a new EDID codes into the NVM
Press OK
With the "left" and "right" keys of the remote control various test patterns can be chosen
Off/On
Use this to return the set to virgin mode. Depends whether the set has been used already.
On
E-fuse mode
Off
ORT mode
Off
When switched "on" the VGA port can be used for UART logging.
Off
Use this for ageing a new LCD panel
128
Red colour temperature setting
128
Green colour temperature setting
128
Red colour temperature setting
Press OK
PC: any pattern that has black and white, YPbPr: SMPTE bar (colour bar), any timing.
0
Red ADC gain
0
Green ADC gain
0
Blue ADC gain
128
Red ADC offset
128
Green ADC offset
128
Blue ADC offset
InValid
Not available for this chassis
2
Three modes, 0: off, 1: adaptive mode, 2: fixed mode
0
Limit threshold
10
Limit threshold
8
Limit threshold
3
Line-in audio gain
2
HDMI audio gain
3
Analogue TV audio gain
2
Digital TV audio gain
2
USB audio gain
6
7
Audio Quality index
Off
Used for audio testing during production
2.1
Defines the installed speaker system
Press OK
Saves the picture quality data to a file "pq.bin" to the root of a FAT formatted USB memory stick
Press OK
Loads the picture quality data from a file "pq.bin" in to the TV
Press OK
Saves the audio quality data to a file "AQ.bin" to the root of a FAT formatted USB memory stick
Press OK
Loads the audio quality data from a file "AQ.bin" in to the TV
Off
FEF Check
Press OK
Exits the Factory mode
TPM9.2HE LA
etc.
How to Activate the Factory mode
To activate the Factory mode, use the following method:
Press the following key sequence on the remote control
transmitter: from the "Menu" press "1999", directly followed
by the "PRE CH" button. Do not allow the display to time
out between entries while keying the sequence.
After entering the Factory mode, the following items are
displayed,
back to
div. table
5.
EN 21
2013-May-30

Advertisement

Table of Contents
loading

Table of Contents