Charging and Battery Pack Information

The Talaria battery pack leverages proven battery cell chemistry, configuration, and enhanced reliability. With the
high-performance lithium-ion battery cells inside of the battery pack, it's well designed to operate under normal
temperatures and environmental conditions based on 60V voltage. The battery pack should not be used outside
of the range of -20°C to 50°C; the Battery Management System (BMS) turns off the power controller outside of this
range. And the battery pack will have the best working efficiency at the range of 10°C to 30°C. The performance
and lifetime of the battery pack will have a reduction if the battery pack is used outside of the range of -20°C to
50°C. The battery pack should not be charged below 0°C.
Caution
The battery pack should not be charged below 0°C, users should wait the temperature to be equal or above
0°C, and then, can charge the battery pack. Otherwise, the battery pack may be damaged.
When the temperature is low, it's normal that the performance of the battery pack will have a reduction, and
lead to a relatively shorter range. After the temperature got to be normal, the performance of the battery pack
and the range will be recovered automatically.
The battery pack has self-protection function, it will work to protect the battery pack from any damages by
over charge and discharge. Frequently over discharge will cause the performance of the battery pack to have
a reduction. When the battery power is low, please charge the battery pack as soon as possible.
The battery pack has no memory function, it could be charged frequently. And to charge the battery pack
frequently can keep it being in a good condition.
If the battery pack will not use for a long time,
60% power, switch off the circuit breaker and unplug the discharge connector. And then, and store the battery
pack in a dry and ventilated place. Otherwise, if the battery pack is not charged for a long time. The low
voltage self-protection function will be activated automatically, then, you need to re-activate the battery pack
to use again.
After the battery pack is fully charged, the voltage should be in the range of 66.5V to 67.2V. If the voltage is
out of the range of 66.5V to 67.2V, then, the battery pack is not fully charged or may got problem. Please
contact the local dealer for solution.
Caution
If the motor and controller got overheating, or the battery pack got low power, the self-protection function will act
to reduce the output power or even shut down the electric motorcycle. It's not a failure or error. After the overheating
cool down, or the battery pack is charged, the performance of the electric motorcycle will recover to be as usual.
please charge the battery pack once for every 3-month to about