Faults
Gear oil exits at the vent hose
Water in the gear oil
Malfunction indicator lamp
lights up or flashes
12-V battery discharged
Values in combination
instrument deleted (time, stop
watch, lap times)
Possible cause
Too much gear oil added
Damaged radial shaft seal ring
or water pump
Malfunction in the electronic
fuel injection
The 12-V battery is not being
charged by the alternator
Unwanted electrical power
consumer
The combination instrument
battery is empty
TROUBLESHOOTING 21
Action
Check the gear oil level. (
Check the radial shaft seal ring and
the water pump.
Check wiring for damage and electri-
cal plug-in connectors for corrosion
and damage.
Read out the fault memory using the
Husqvarna Motorcycles diagnostics
tool.
Check the charging voltage.
Check the stator winding of the alter-
nator.
Check the open-circuit current.
Change combination instrument bat-
tery. (
p. 115)
p. 134)