Terex GS30MD-3169 Operator's Manual page 31

Table of Contents

Advertisement

Second Edition • First Printing
At the Ground Controls
1
Select a test area that is firm, level and free of
hazards.
2
Be sure the batteries are connected.
3
Pull out the platform and ground red
Emergency Stop button to the on position.
4
Turn the key switch to ground control.
5
Observe the diagnostic LED readout on the
platform controls.
Result: The LED should look like the picture
below.
6
Observe the diagnostic LCD readout on the
ground controls.
Result: The LCD should display the area of
operation, and hour meter.
SELECT IN/OUT
00000.0 Hours
Test Emergency Stop
7
Push in the ground red Emergency Stop button
to the off position.
Result: No functions should operate.
8
Pull out the red Emergency Stop button to the
on position.
Part No. 1301858GT
Test the Up/Down Functions
The audible warnings on this machine and the
standard horn all come from the same central
alarm. The horn is a constant tone. The descent
alarm sounds at 60 beeps per minute. The alarm
sounds at 180 beeps per minute when the pothole
guards have not deployed and when the machine
is not level. An optional automotive-style horn is
also available.
9
Do not press the lift function enable button.
10 Press the platform up or platform down button.
Result: The lift function should not operate.
11 Do not press the platform up or platform down
buttons.
12 Press the lift function enable button.
Result: The lift function should not operate.
13 Press and hold the lift function enable button,
and press the platform up button.
Result: The outdoor area of operation should
be selected and the platform should raise.
14 Press and hold the lift function enable button,
and press the platform down button.
Result: The platform should lower. The
descent alarm should sound while the platform
is lowering.
GS
-1330m
Operator's Manual
Inspections
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Genie gs-1330m

Table of Contents