Flueing Arrangements - Horizontal Termination (Flex) - Regency

These flueing systems, in combination with GF1500L, have been tested and listed as a Direct Vent system by AGA. The location of the termination cap must
conform to the requirements in the Flue Terminal Locations diagram from the "Exterior Flue Termination Locations" section.
FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the GF1500L using a flexible vent.
FPI Kit #
Length Contains:
#946-615
1.2 m
1)
2)
3)
4)
#946-618
1.8 m
5)
6)
7)
#946-616
3 m
8)
9)
127mm dia. flue pipe
203mm dia.
Flue pipe
203mm flexible liner (Kit length)
127mm flexible liner (Kit length)
spring spacers
thimble
AstroCap termination cap
screws
tube of Mill Pac
plated screws
S.S. screws #8 x 38mm drill point
Wall Thimble
(Mandatory in all
Horizontal Terminations)
spring spacer

Direct Vent System

®
Flue Guard - if required *
Part 946-604/P
(Part #946-506/P)
AstroCap XL
TM
Termination Cap
(Part #946-623/P)
• Liner sections should be continuous without any joints or seams.
• Only Flex pipe purchased from FPI may be used for Flex installations.
• Horizontal flue must be supported every 0.9m.
• A wall thimble is mandatory for all horizontal terminations due to
high temperatures.
installation
Greenfire® GF1500L-2 Gas Fireplace
|
29