Poe Status - ZyXEL Communications GS1915 Series User Manual

8/24-port gigabit smart managed layer-2 switch
Table of Contents

Advertisement

Table 33 Basic Setting > Port Setup (continued)
LABEL
Flow Control
802.1p Priority
Apply
Cancel

8.7 PoE Status

Note: The following screens are available for the PoE models only.
A powered device (PD) is a device such as an access point or a switch, that supports PoE (Power over
Ethernet) so that it can receive power from another device through an Ethernet port.
In the figure below, the IP camera and IP phone get their power directly from the Switch. Aside from
minimizing the need for cables and wires, PoE removes the hassle of trying to find a nearby electric
outlet to power up devices.
Figure 72 Powered Device Examples
You can also set priorities so that the Switch is able to reserve and allocate power to certain PDs.
Note: The PoE (Power over Ethernet) devices that supply or receive power and their
connected Ethernet cables must all be completely indoors.
To view the current amount of power that PDs are receiving from the Switch, click Basic Setting > PoE
Setup.
Chapter 8 Basic Setting
DESCRIPTION
A concentration of traffic on a port decreases port bandwidth and overflows buffer memory
causing packet discards and frame losses. Flow Control is used to regulate transmission of signals
to match the bandwidth of the receiving port.
The Switch uses IEEE 802.3x flow control in full duplex mode and backpressure flow control in half
duplex mode.
IEEE 802.3x flow control is used in full duplex mode to send a pause signal to the sending port,
causing it to temporarily stop sending signals when the receiving port memory buffers fill.
Back Pressure flow control is typically used in half duplex mode to send a "collision" signal to the
sending port (mimicking a state of packet collision) causing the sending port to temporarily stop
sending signals and resend later. Select Flow Control to enable it.
This priority value is added to incoming frames without a (802.1p) priority queue tag.
Click Apply to save your changes to the Switch's run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to save
your changes to the non-volatile memory when you are done configuring.
Click Cancel to begin configuring this screen afresh.
GS1915 Series User's Guide
97

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs1915-8Gs1915-8epGs1915-24eGs1915-24ep

Table of Contents