Inlet Valve Fitting Removal/Service

Inlet Valve Fitting
Removal/Service
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing fluid
and moving parts, disconnect power and follow the
Pressure Relief Procedure when you stop spraying
and before cleaning, checking, or servicing the
equipment.
Move sprayer to a non-hazardous area before servicing.
1.
Engage trigger lock and pull prime/spray valve UP to
release pressure.
ti18912a
2.
Remove material cup, flexible suction tube, and
unplug.
ti18930a
NOTICE
When removing flexible suction tube from sprayer, make
sure to pull directly on top fitting of flexible suction tube.
Flexible suction tube will become damaged if pulled
from bottom or on flexible portion.
3.
Hold sprayer upside-down and use wrench to loosen
and remove inlet valve fitting, inlet valve, and spring.
NOTE: Make sure the spring also comes out. Use nee-
dle-nose pliers to remove if needed. Inlet cavity should
be completely empty (as shown below).
22
ti16700a
ti15505b
4.
Clean as much excess material from inlet cavity as
possible. Make sure you also clean spring (a), inlet
valve (b), o-ring (c), and top of inlet valve fitting (d).
5.
Use a thin wire less than 1/16 in. (such as a paper clip)
to check that the outlet valve fitting moves freely. If
valve does not move freely, perform Outlet Valve
Fitting Repair, page 23.
Installation
NOTE: Before installing, make sure o-ring (c) is installed
on poppet valve (b). A needle-nose pliers may also be used
to install parts A - C.
1.
Place poppet valve (b) with spring (a) on top of inlet
valve fitting (d). Push inlet fitting up into pump cavity.
a
b
c
d
2.
Hold inlet in place and turn sprayer upside-down.
Remove inlet valve fitting and visually check to see
that inlet valve has seated correctly.
3.
Replace inlet fitting and use wrench to tighten to
10 ft-lb (14 N•m).
NOTICE
Do NOT over-tighten inlet valve fitting. Damage to the
equipment will occur.
4.
Use a pencil or thin rod to lightly push on inlet valve to
make sure it moves up and down freely. Perform Start-
ing New Job procedure, page 11.
ti18929a
ti15502b
ti15500a
ti15537b
3A2587L