SERVICE PROCEDURES (REMOVAL/REPLACEMENT)
4 To gain access, remove the screws holding the panel in
place .
5 . Pull the panel towards the back of the oven to remove .
6 . Cavity probe is located ABOVE and to the RIGHT of the
cavity motor .
7 . Disconnect the 2 BROWN probe wires at the temperature
probe .
8 . The probe can now be removed from inside the oven .
9 . Reinstall the replacement probe in reverse manner .
Door To Cavity Seal Adjustments
1 . Close the door, and determine the area (s) of air leakage .
(Use of a dollar bill between the door, and cavity seal, is a
suffi cient reference .
2 Open the door and move upper, and lower, BA plate hold
down counter sunk screws .
3 . Position the door rod upper, and lower, BA plates to
increase, or decrease, pressure on the cavity seal, where
needed . (Refer to fi gures 1, and 2, )
Part # MPSM07 (03/24/08)
BA plate
secured to
inner mount
hole reduces
pressure on
l .
cavity sea
Fig . 1
RH Door Frame To Cavity Seal Adjustment
The RH door frame to cavity seal pressure can be increased or
decreased, by adjustment of the handle latch engagement
hook tension before the door handle locks closed .
Loosen the small set screw, position the handle hook target in
or out, and test for eff ect . Once the proper secure the target
set screw .
RH door
frame to
cavity seal
adjustment
area .
BA plate secured
to outer mount
hole increases
pressure on
cavity seal
Fig . 2
Page 59