minimum mantel or shelf clearances

WARNING
!
Risk of fi re!
Maintain all specifi ed air space clearances to combustibles.
Failure to comply with these instructions may cause a fi re or cause the appliance to overheat.
Ensure all clearances (i.e. back, side, top, vent, hearth, mantel, front, etc.) are clearly maintained.
When the appliance is rear vented, a mantel or shelf may be installed above the GDS25-1 at a minimum distance
of 8" (203mm).
COMBUSTIBLE
MANTEL OR
TRIM MATERIAL
8" (203mm)
MIN.
COMBUSTIBLE
12" (305mm)
MAX. MANTEL DEPTH
2" (51mm)
2"
(51mm)
installation
NON-COMBUSTIBLE
BRICK
0" (0mm) IF NON-
COMBUSTIBLE
FINISHING IS
USED SUCH AS
BRICK AND STONE
1" (25mm)
24 1/2"
(622mm)
W415-2347 / C / 09.21.20
EN
23