General Information; Unit Nameplate; Compressor Nameplate; Gas Heat Nameplate - Trane IntelliPak 1 Installation, Operation And Maintenance Manual

Commercial packaged rooftop air conditioners with vav or szvav controls and eflex/ edrive
Table of Contents

Advertisement

General Information

Unit Nameplate

One Mylar unit nameplate is located on the outside of
enclosure. It includes the unit model number, serial
number, electrical characteristics, weight, refrigerant
charge, unit wiring diagram numbers, as well as other
pertinent unit data. A small metal nameplate with the
Model Number, Serial Number, and Unit Weight is
located just above the Mylar nameplate, and a third
nameplate is located on the inside of the control panel
door.

Compressor Nameplate

The Nameplate for the Scroll Compressor is located on
the compressor lower housing. Max amps is listed on
the nameplate and is the absolute highest amp load on
the compressor at any operating condition (does not
include locked rotor amps or inrush). This value should
never be exceeded.

Gas Heat Nameplate

The nameplate for the Gas Heater is located on the
inside of the gas heat enclosure. Allowable operating
values of Min and Max input rate, manifold pressure,
and air rise for the heater is listed on the nameplate.

Unit Description

Each single-zone rooftop air conditioner ships fully
assembled and charged with the proper refrigerant
12
quantity from the factory. An optional roof curb,
specifically designed for the S_HL units is available
from Trane. The roof curb kit must be field assembled
and installed according to the latest edition of the roof
curb installation manual.
Trane Commercial Rooftop Units are controlled by a
Symbio 800 control system that consists of a network
of modules and are referred to as Low Level Intelligent
Devices (LLID). The acronym (LLID) is used extensively
throughout this document when referring to the control
system network. These modules through Proportional/
Integral control algorithms perform specific unit
functions which provide the best possible comfort level
for the customer.
They are mounted in the control panel and are factory
wired to their respective internal components. They
receive and interpret information from other unit
modules, sensors, remote panels, and customer binary
contacts to satisfy the applicable request for
economizing, mechanical cooling, heating, and
ventilation. Refer to the following discussion for an
explanation of each module function.
N N o o t t e e : : The Symbio ™ 800 coin cell tray should never be
taken out unless the Symbio 800 is powered on
or the Symbio 800 needs to be powered on
shortly after replacing the battery. Failure to do
this may shorten the battery life.