Intellifire™ Touch Ignition System Wiring - Heatilator GDST4336IFT Installation Manual

Hide thumbs Also See for GDST4336IFT:
Table of Contents

Advertisement

Accessories Requirements
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors could
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
Heatilator • GDST4336IFT, GDFL4136IFT Installation Manual • 2480-980 Rev. B • 3/17
B. IntelliFire™ Touch Ignition System Wiring
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.2, IntelliFire
Diagram.
• This appliance is equipped with an Intellifi re control valve
which operates on a 6 volt system.
TM
Touch (IPI) Wiring
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gdfl4136ift

Table of Contents