Heatilator GDST4336IFT Installation Manual page 31

Hide thumbs Also See for GDST4336IFT:
Table of Contents

Advertisement

Rear Vent - Vertical Termination
One Elbow
V
1
Figure 4.24
Two Elbows
V
1
Figure 4.25
Heatilator • GDST4336IFT, GDFL4136IFT Installation Manual • 2480-980 Rev. B • 3/17
H
1
INSTALLED
HORIZONTALLY
H
2
V
Minimum
1
1 ft.
305 mm
2 ft.
610 mm
3 ft.
914 mm
4 ft.
1.2 m
5 ft.
1.5 m
V
+ H
= 40 ft (12.2 m) Maximum
1
1
V
Minimum
1
Back to Back 90° Elbows
2 ft
610 mm
4 ft.
1.2 m
5 ft.
1.5 m
6 ft.
1.8 m
V
+ H
+ H
= 50 ft (15.2 m) Maximum
1
1
2
H
+ H
= 16 ft (4.9 m) Maximum
1
2
H
1
H
Maximum
1
3 ft.
914 mm
5 ft.
1.5 m
7 ft.
2.1 m
8 ft
2.4 m
8 ft
2.4 m
H
+ H
Maximum
1
2
3 ft.
914 mm
6 ft.
1.8 m
9 ft.
2.7 m
10 ft.
3 m
12 ft.
3.7 m
31