Product Specific Information; Appliance Certification; Glass Specifications; Btu Specifications - Heat & Glo 6000CL-IFT-S Owner's Manual

Hide thumbs Also See for 6000CL-IFT-S:
Table of Contents

Advertisement

2 2

Product Specific Information

A. Appliance Certification
MODELS: 6000CL-IFT-S, 6000CL-IFTLP-S,
6000CL-IFT-G, 6000CL-IFTLP-G,
8000CL-IFT-S, 8000CL-IFTLP-S,
8000CL-IFT-G, 8000CL-IFTLP-G
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Heater
STANDARD: CSA / ANSI Z21.88:19 • CSA 2.33:19
This product is listed to ANSI standards for "Vented Gas
Fireplace Heaters" and applicable sections of "Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles", and "Gas Fired Appliances for
Use at High Altitudes".
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
6
Heat & Glo • 6000CL-IFT, 8000CL-IFT Owner's Manual • 2504-981 Rev. K • 12/20
B. Glass Specifications
This appliance is equipped with 5 mm ceramic glass. Re-
place glass only with 5 mm ceramic glass. Please contact
your dealer for replacement glass.
C. BTU Specifications
Models
(U.S. or Canada)
6000CL-IFT
(0-2000 FT)
(NG)
6000CL-IFTLP
(0-2000 FT)
(Propane)
8000CL-IFT
(0-2000 FT)
(NG)
8000CL-IFTLP
(0-2000 FT)
(Propane)
Maximum
Orifice
Minimum
Input
Size
Input BTU/h
BTU/h
(DMS)
35,000
18,000
#33
34,000
20,000
#51
40,000
20,000
#31
40,000
23,000
#49