Specifications

Auto Power On: 12 V AC/DC or greater
Display: LED display with polarity and AC indicator
Reaction Time: 1 second maximum
Test Current: 3.5 mA maximum
Voltage Range: 12 to 690 Volts (AC or DC)
Frequency Range: 0 to 60 Hz
Internal Load: 1.3 W at 230 V (approximately)
Peak Current: 0.25 A maximum
Locating Hot Conductors: 100 to 690 V (50 to 60 Hz)
Charge Voltage: 100 V or greater
Continuity Verification: 0 to 800 k
Test Current: 2 A
Charge Voltage: 100 V or greater
Operating Time: 30 seconds
Standby Time: 30 minutes
Operating/Storage Conditions: -10 C to 50 C (14 F to 122 F)
0% to 85% Relative Humidity
Overvoltage Protection: Category III, 700 Volts
Pollution Degree: 2
Protection Category: IP 50