Table of Contents

Advertisement

PROBLEM
Gas supply or gas valve
is suspect.
Temperature probe is
suspect.
For use with H50 Series fryers manufactured with Minco Thermistor probes only.
F
OHMS
C
F
60
1059
16
130
65
1070
18
135
70
1080
21
140
75
1091
24
145
80
1101
27
150
85
1112
29
155
90
1122
32
160
95
1133
35
165
100
1143
38
170
105
1154
41
175
110
1164
43
180
115
1174
46
185
120
1185
49
190
125
1195
52
195
PROBABLE CAUSES
A.
Gas valve in non-CE is in OFF position.
B.
Gas valve in non-CE is in OFF position.
C.
Improper incoming gas pressure.
Check:
Incoming gas pressure is in
accordance with the appropriate table on
Page 1-23 of this manual.
D.
Improper burner manifold gas pressure.
Check:
Burner manifold pressure is in
accordance with the appropriate table on
Page 1-7 of this manual.
A. Damaged probe.
Check:
While it is still in the frypot,
inspect the probe for damage.
B. Failed probe.
Check 1: Determine the temperature of
the oil in the frypot using a thermometer
or pyrometer placed at the tip of the
probe, then check the for a resistance
through J3 pins 2 and 6 (J1 pins 2 and 6
for the left side of a dual vat) approxi-
mately equal to that given in the Probe
Resistance Chart for the corresponding
temperature.
Check 2:
Check
for
megaohms of resistance through each of
the previously tested pins to ground.

Probe Resistance Chart

OHMS
C
F
1204
54
200
1216
57
205
1226
60
210
1237
63
215
1247
66
220
1258
68
225
1268
71
230
1278
74
235
1289
77
240
1299
79
245
1309
82
250
1320
85
255
1330
88
260
1340
91
265
CORRECTIVE ACTION
A.
Place gas valve in ON position.
B.
Place gas valve in ON position.
C.
Bring incoming gas pressure into accor-
dance with the appropriate table on Page
1-23 of this manual.
D.
Adjust the gas valve (see procedure 1.4
of this manual) to bring the burner mani-
fold pressure into accordance with the
appropriate table on Page 1-7 of this
manual. If the manifold pressure cannot
be properly adjusted, replace the gas
valve.
A. Replace the probe if the body is bent,
dented, or cracked, or if its wiring is
burned, broken, frayed, or kinked.
B. If probe does not test OK for both
checks, replace the probe.
at
least
5
OHMS
C
F
OHMS
1350
93
270
1493
1361
96
275
1503
1371
99
280
1514
1381
102
285
1524
1391
104
290
1534
1402
107
295
1544
1412
110
300
1554
1422
113
305
1564
1432
116
310
1574
1442
118
315
1584
1453
121
320
1594
1463
124
325
1604
1473
127
330
1614
1483
129
335
1624
1-35
C
F
OHMS
C
132
340
1634
171
135
345
1644
174
138
350
1654
177
141
355
1664
179
143
360
1674
182
146
365
1684
185
149
370
1694
188
152
375
1704
191
154
380
1714
193
157
385
1724
196
160
390
1734
199
163
395
1744
202
166
400
1754
204
168
405
1764
207

Advertisement

Table of Contents
loading

Table of Contents