CE Standard
Burner Manifold Gas Pressures
for Fryers Manufactured After April 1999
Gas
Natural Gas Lacq
(G20) under 20 mbar
Natural Gas Gronique *
(G25) under 25 mbar
Natural Gas Gronique
(G25) under 20 mbar
Butane/Propane
(G30) at 28/30 or 50 mbar
Propane
(G31) under 37 or 50 mbar
* Belgian G25 = 7,0 mbar (single or dual)
5. To adjust the burner gas pressure, remove the cap from the gas valve regulator and adjust to the
correct pressure.
Non-CE
Valve
6. Place the fryer power switch (and the gas valve in non-CE fryers) in the OFF position. Remove
the fitting from the pressure tap hole and reinstall the pressure tap plug.
Pressure (mbar)
Single
Dual
Vat
Vat
7
7
10
10
10
10
17
17
20
20
Non-CE Standard
Burner Manifold Gas Pressures
Gas
Natural
Propane
Earlier Model CE Valve
GAS VALVE REGULATOR CAP
1-6
CE Standard
Burner Manifold Gas Pressures
for Fryers Manufactured Through April 1999
Gas
Natural Gas Lacq
(G20) under 20 mbar
Natural Gas Gronigue *
(G25) under 25 mbar
Natural Gas Gronigue
(G25) under 20 mbar
Butane
(G30) at 28/30 or 50 mbar
Propane
(G31) under 37 or 50 mbar
* Belgian G25 = 7,0 mbar (single) or 6,5 (dual)
Pressure
3" W.C.
0.73 kPa
8.25" W.C.
2.5 kPa
Pressure (mbar)
Single
Dual
Vat
Vat
7
6,5
10
9
10
9
17
16,5
20,2
18,5
Later Model
CE Valve