Frymaster H50 Series Service And Parts Manual page 38

Table of Contents

Advertisement

With Interface Board 806-3398 or
Two
807-1006
(FV/DV),
J1 PIN 8
Heat Relay
(K1 Fixed)
(K2 Replaceable)
2 (PWR)
LED
PWR
High Voltage
IGNITION
to Ignitor
MODULE
V2D
1 (GV)
LED
J1 PIN 9
HIGH
LIMIT
SWITCH
DRAIN
SAFETY
SWITCH
GAS
VALVE
LEFT VAT
24 VOLT CIRCUIT
807-2971
(FV/DV), or
24V
TRANSFORMER
FV = Full Vat
DV = Dual Vat
Flame Sensor
Flame Sensor
This switch used only with
built-in filtration systems.
1-33
106-0386
and
807-3365
(DV) Ignition Modules
LED 3 (24V)
J3 PIN 8
PWR
IGNITION
MODULE
V1S (FV) OR V1D (DV)
J3 PIN 9
HIGH
LIMIT
SWITCH
DRAIN
SAFETY
SWITCH
GAS
VALVE
FULL OR RIGHT VAT
Heat Relay
(K2 Fixed)
(K3 Replaceable)
LED 4 (PWR)
High Voltage
to Ignitor
LED 5 (GV)

Advertisement

Table of Contents
loading