Probe Resistance Chart; Ato (Automatic Top-Off)/Manual Top-Off And Filtration Service Procedures - Frymaster FilterQuick easyTouch FQG60T Service Manual

Hide thumbs Also See for FilterQuick easyTouch FQG60T:
Table of Contents

Advertisement

1.18

Probe Resistance Chart

For use with FQG60-T fryers manufactured with Minco RTD probes only.
F
OHMS
C
60
1059
16
130
65
1070
18
135
70
1080
21
140
75
1091
24
145
80
1101
27
150
85
1112
29
155
90
1122
32
160
95
1133
35
165
100
1143
38
170
105
1154
41
175
110
1164
43
180
115
1174
46
185
120
1185
49
190
125
1195
52
195

1.19 ATO (Automatic Top-Off)/Manual Top-Off and Filtration Service Procedures

The automatic top-off system is activated when the oil level falls below the top sensor in the front of the frypot. The signal
is sent to the FIB (Filter Interface Board) which sends a signal to the VIB (Valve Interface Board) to engage the return
actuator to the frypot and turn on the ATO pump. The pump draws oil from the JIB (Jug In Box) through the rear return
manifold into the rear of the frypot. Once the oil level has satisfied the sensor, the pump turns off and the actuator closes.
The ATO function only operates when the vat is in idle state. If a cook, filter or other operation starts, the ATO function is
cancelled. Systems without ATO still use an ATO probe to detect low oil. The signal still follows the path of the ATO, but
the controller displays OIL LEVEL LOW, MANUALLY ADD OIL. Once oil is manually added pressing the orange button resets
the FIB board.
The FIB (Filter Interface Board) also oversees and controls filtration and bulk oil functions. It receives and sends data over
the CAN (Controller Area Network) to and from various sensors, boards and controllers. It activates the filtration cycle
sending information to the VIB (Valve Interface Board) boards controlling when actuators should open and close.
The FIB board is located inside the control box. The power for the FIB board, the filter pump relay and top off pump is
supplied from the 24VDC power supply from the transformer box. The 24VDC power supply also provides power, which
passes through the FIB board to the VIB board, to the rotary actuators. The power for the VIB board microprocessor is
supplied from the SIB.
The 24VAC transformer powers the fresh oil solenoid for bulk oil.
1.19.1 Auto Top Off Troubleshooting
Problem
Fryer tops off cold.
No power to FIB board
Probe Resistance Chart
F
OHMS
C
F
1204
54
200
1216
57
205
1226
60
210
1237
63
215
1247
66
220
1258
68
225
1268
71
230
1278
74
235
1289
77
240
1299
79
245
1309
82
250
1320
85
255
1330
88
260
1340
91
265
Probable Causes
Incorrect setpoint.
A.
J1 connection unplugged.
B.
Power supply malfunction.
OHMS
C
F
OHMS
1350
93
270
1493
1361
96
275
1503
1371
99
280
1514
1381
102
285
1524
1391
104
290
1534
1402
107
295
1544
1412
110
300
1554
1422
113
305
1564
1432
116
310
1574
1442
118
315
1584
1453
121
320
1594
1463
124
325
1604
1473
127
330
1614
1483
129
335
1624
Ensure setpoint is correct.
A.
Check to ensure J1 on front of FIB board is fully locked
into connector.
B.
Check that proper voltage is present at the power
supply. See table in section 1.19.4.
1-28
C
F
OHMS
132
340
1634
135
345
1644
138
350
1654
141
355
1664
143
360
1674
146
365
1684
149
370
1694
152
375
1704
154
380
1714
157
385
1724
160
390
1734
163
395
1744
166
400
1754
168
405
1764
Corrective Action
C
171
174
177
179
182
185
188
191
193
196
199
202
204
207

Hide quick links: