Probe Resistance Chart; Manual Top-Off And Filtration Service Procedures; Fib Troubleshooting - Frymaster FilterQuick FQG80T Service Manual

Hide thumbs Also See for FilterQuick FQG80T:
Table of Contents

Advertisement

1.18

Probe Resistance Chart

For use with FQG80T/100T/120T fryers manufactured with Minco RTD probes only.
F
OHMS
C
60
1059
16
130
65
1070
18
135
70
1080
21
140
75
1091
24
145
80
1101
27
150
85
1112
29
155
90
1122
32
160
95
1133
35
165
100
1143
38
170
105
1154
41
175
110
1164
43
180
115
1174
46
185
120
1185
49
190
125
1195
52
195

1.19 Manual Top-Off and Filtration Service Procedures

The fryer uses an ATO probe to detect low shortening level. When the shortening falls below the probe, the controller
displays LOW OIL DETECTED, ADD OIL FROM THE NEXT FRYPOT or ADD FRESH SHORTENING. Once the shortening is
manually added, press the check mark.
The FIB (Filter Interface Board) also oversees and controls filtration. It receives and sends data over the CAN (Controller
Area Network) to and from various sensors, boards and controllers. It activates the filtration cycle sending information to
the VIB (Valve Interface Board) boards controlling when actuators should open and close.
The FIB board is located inside the control box. The power for the FIB board and the filter pump relay is supplied from the
24VDC power supply from the transformer box. The 24VDC power supply also provides power, which passes through the
FIB board to the VIB board, to the rotary actuators. The power for the VIB board microprocessor is supplied from the SIB.

1.19.1 FIB Troubleshooting

Problem
No power to FIB board
FQ4000 displays E29 TOP
OFF PROBE FAILURE – CALL
SERVICE
Probe Resistance Chart
F
OHMS
C
F
1204
54
200
1216
57
205
1226
60
210
1237
63
215
1247
66
220
1258
68
225
1268
71
230
1278
74
235
1289
77
240
1299
79
245
1309
82
250
1320
85
255
1330
88
260
1340
91
265
Probable Causes
A.
J1 connection unplugged.
B.
Power supply malfunction.
A.
Shorted or Open ATO RTD probe
B.
Bad Connection
OHMS
C
F
OHMS
1350
93
270
1493
1361
96
275
1503
1371
99
280
1514
1381
102
285
1524
1391
104
290
1534
1402
107
295
1544
1412
110
300
1554
1422
113
305
1564
1432
116
310
1574
1442
118
315
1584
1453
121
320
1594
1463
124
325
1604
1473
127
330
1614
1483
129
335
1624
A.
Check to ensure J1 on front of FIB board is fully locked
into connector.
B.
Check that proper voltage is present at the power
supply. See table in section 1.19.4.
A.
With ATO probe covered in oil, press the "?" button.
Press the down arrow. Press Software Version. Press
the down arrow and ensure actual vat temperature
and ATO RTD temperature are relatively close. If
temperature reading is missing, unplug the ATO probe
from the SIB board and check ATO probe resistance. If
probe is bad, replace the probe.
B.
Ensure ATO probe is connected properly to SIB board.
Ensure that the connector is terminated properly.
1-28
C
F
OHMS
132
340
1634
135
345
1644
138
350
1654
141
355
1664
143
360
1674
146
365
1684
149
370
1694
152
375
1704
154
380
1714
157
385
1724
160
390
1734
163
395
1744
166
400
1754
168
405
1764
Corrective Action
C
171
174
177
179
182
185
188
191
193
196
199
202
204
207