Application Guidelines; Overview: Application Guidelines; Setting Up The Space Heating System - In Case Of Dedicated Gas Boiler - Daikin INTERGAS Altherma NHY2KOMB28AA Installer's Reference Manual

Hide thumbs Also See for INTERGAS Altherma NHY2KOMB28AA:
Table of Contents

Advertisement

Accessories Part number
EKFGP4828
EKFGP6340
EKFGP6344
EKFGP6341
EKFGP6342
EKFGP6324
EKFGP6333
EKFGP4481
EKFGV1101
EKFGV1102
EKFGW4001
EKFGW4002
EKFGW4004
EKFGW4085
EKFGW4086
EKGFP1289
EKGFP1299
INFORMATION
For extra configuration options regarding the flue gas
system, visit http://fluegas.daikin.eu/.
EJHA04AAV3 + NHY2KOMB28+32AA
Daikin Altherma H Hybrid
4P556861-1A – 2019.05
Description
Chimney connection 80/125
Extension Flex PP 80 L=10 m
Extension Flex PP 80 L=15 m
Extension Flex PP 80 L=25 m
Extension Flex PP 80 L=50 m
Connector-flex-flex PP 80
Spacer PP 80-100
Fixation Ø100
Chimney connection 60/10
air intake Dn.80 C83
Connection set 60/10-60 Flue/
Air intake Dn.80 C53
Extension P BM-Air 80×500
Extension P BM-Air 80×1000
Extension P BM-Air 80×2000
Elbow PP BM-Air 80 90°
Elbow PP BM-Air 80 45°
Elbow PP/GALV 60/100 50°
Kit horizontal low profile PP/
GLV 60/100 (UK only)

7 Application guidelines

INFORMATION
For the installation of the flue and air supply duct material,
see the manual included with the materials. Contact the
manufacturer of the relevant flue and air supply duct
materials for extensive technical information and specific
assembly instructions.
7
Application guidelines
7.1

Overview: Application guidelines

The purpose of the application guidelines is to give a glance of the
possibilities of the heat pump system.
NOTICE
▪ The illustrations in the application guidelines are meant
for reference only, and are NOT to be used as detailed
hydraulic
diagrams.
dimensioning and balancing are NOT shown, and are
the responsibility of the installer.
▪ For more information about the configuration settings to
optimize
heat 
"10 Configuration" on
This chapter contains application guidelines for:
▪ Setting up the space heating system
▪ Setting up the domestic hot water tank
▪ Setting up the energy metering
▪ Setting up the power consumption control
▪ Setting up an external temperature sensor
7.2
Setting up the space heating
system – In case of dedicated gas
boiler
The heat pump system supplies leaving water to heat emitters in one
or more rooms.
Because the system offers a wide flexibility to control the
temperature in each room, you need to answer the following
questions first:
▪ How many rooms are heated by the heat pump system?
▪ Which heat emitter types are used in each room and what is their
design leaving water temperature?
Once the space heating requirements are clear, Daikin recommends
to follow the setup guidelines below.
NOTICE
If an external room thermostat is used, the external room
thermostat will control the room frost protection. However,
the room frost protection is only possible if the leaving
water temperature control on the unit's user interface is
turned ON.
INFORMATION
In case an external room thermostat is used and room frost
protection needs to be guaranteed in all conditions, then
you have to set auto emergency [A.6.C] to 1.
The
detailed
hydraulic
pump
operation,
see
page 56.
Installer reference guide
17