II. RECEIPT INSPECTION
All Traulsen products are factory tested for performance and
are free from defects when shipped. The utmost care has
been taken in crating this product to protect against damage
in transit. All interior fittings have been carefully secured and
the legs or casters are boxed and strapped inside to prevent
damage. Door keys will be attached to the handle with a
nylon strip. The handle is protected by an easily removable
nylon netting.
You should carefully inspect your Traulsen unit for
damage during delivery. If damage is detected, you
should save all the crating materials and make note
on the carrier's Bill Of Lading describing this. A freight
claim should be filed within 10 days. If damage is sub-
sequently noted during or immediately after installation,
contact the respective carrier and file a freight claim.
Under no condition may a damaged unit be returned to
Traulsen without first obtaining written permission (return
authorization).
III. INSTALLATION
III. a - LOCATION:
Select a proper location for your Traulsen unit, away
from extreme heat or cold. Allow enough clearance be-
tween the unit and the side wall in order to make use of
the door stay open feature at 120° (self-closing feature
operates up to 90°). The door(s) must be able to open
a minimum of 90° in order to make use of the maximum
clear door width available.
III. b - PACKAGING:
All Traulsen units are shipped from the factory bolted
to a sturdy wooden pallet and packaged in a durable
cardboard container. The carton is attached to the
wooden skid with the use of large staples. These should
first be removed to avoid scratching the unit when
lifting off the crate.
Most exterior stainless steel surfaces have a protec-
tive vinyl covering to prevent scratching during
manufacturing, shipping and installation. After the unit
is installed in place of service, remove and discard the
covering from all surfaces.
To remove the wooden pallet, first if at all possible, we
suggest that the cabinet remain bolted to the pallet
during all transportation to the point of final installa-
tion. The bolts can then be removed with a 3/4" socket
wrench.
Avoid laying the unit on its front, side or back
for removal of the pallet.
NOTE: DO NOT LAY THE UNIT ON ITS SIDE DURING
TRANSPORTATION OR INSTALLATION.
III. INSTALLATION (continued)
III. c - INSTALLING LEGS OR CASTERS:
6" high stainless steel legs are supplied standard for
all Traulsen reach-in and pass-thru units. Casters in
lieu of legs are available as an optional accessory for
the same models. These are shipped from the fac-
tory packed inside a cardboard box which is strapped to
one of the shelves. Remove the nylon strap and open
the box, it should contain either four (4) legs or four (4)
casters and sixteen (16) bolts.
WARNING: THE CABINET MUST BE BLOCKED AND
STABLE BEFORE INSTALLING LEGS OR CASTERS.
To install the legs or casters, first raise and block
the reach-in a minimum of 7" from the floor.
installing legs, thread the legs into the threaded holes
on the bottom of the cabinet (see figure below). Be cer-
tain that all legs are tightly secured (legs and casters
should be tightened to 300 inch/pounds, max).
the unit is set in its final position, it is important for proper
operation that the unit be level. The legs are adjust-
able for this purpose, turn the bottom of the leg counter-
clockwise to raise it, clockwise to lower it. Level the
unit from front to back as well as side to side in this
manner, using a level placed in the bottom of the
cabinet.
Please note that Traulsen units are not designed to
be moved while on legs. If the unit requires moving, a
pallet jack or forklift should be used to prevent dam-
age.
For installing casters, the casters are "plate" type,
and require the use of four (4) bolts each to secure them
firmly to the cabinet bottom at each corner (see figure be-
low). The caster bolts are tightened using a 1/2" socket
wrench.