Basic Setup; Alarm Setup - Furuno 9ZWFM8800S Operator's Manual

Vhf radiotelephone
Table of Contents

Advertisement

4.

BASIC SETUP

4.1

Alarm Setup

This section provides the procedures for setting up various alarms. The alarm
menu enables/disables internal and external alarms. Note that the
Distress/Urgency alarm cannot be disabled.
Disabling/enabling old position alarm in manual position entry mode
This alerts the operator when manually entered position data is older by the
number of hours or minutes set in the next Position Older field.
1. Press the MENU key.
SETUP MENU on transceiver unit
2. ALARM is selected; press the ENT key to display the ALARM menu.
OLD POSITION
POSITION OLDER 4H
EXT ALARM
ALARM MENU on transceiver unit
3. Rotate the CH knob (or press up / down arrow key) to choose OLD POSITION
from the ALARM MENU and press the ENT key. The setting window appears.
4. Rotate the CH knob (or press up / down arrow key) to choose ON or OFF as
appropriate and press the ENT key. If you chose ON, the message "Warning:
Update position" appears when manually entered position is older than the
time set on the ALARM MENU.
5. Press the CANCEL key twice to return to the standby display.
**** SETUP MENU ****
ALARM
AUTO ACK
ERASE LOG
MEMORY CHANNEL
MESSAGE FILE ENTRY
**** ALARM MENU ****
SETUP MENU on remote handset
OFF
DSTRS/URG
 
ALARM MENU on remote handset
(You can get same information by
scrolling with up / down arrow
keys)
* SETUP MENU *
ALARM
AUTO ACK
ERASE LOG
MEMORY CH
MESSAGE FILE
* ALARM MENU *
OLD POSITION
OFF
POSITION OLDER
4H
4-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fm-8800sFm-8800d9zwfm8800d

Table of Contents