SETTINGS

Limit switch adjustments must be completed
before running contact reverse test.
28
1. Test contact reverse.
• Open door using wall control.
• Lay 2" x 4" board
door opening. Fig. 7-3.
• Close door using wall control.
– Door should stop and reverse
within 2 seconds of contacting the board.
– If door does not reverse properly:
a. Decrease closing force a small amount
by turning the "CLOSE" force adjustment
screw slightly counterclockwise.
b. Test contact reverse again.
c. Repeat steps a. and b. until contact
reverse works properly.
*
If you don't have a 2" x 4" board handy, any object
1-1/2 inches high that can withstand being hit by the
garage door without sustaining damage is fine.
NOTE: If door is stopping but not reversing,
"CLOSE" limit switch must be moved closer to
door.
SECT 8—BATTERY & VISOR CLIP
1. Install / replace battery Fig. 8-1.
• Using a pen or similar object, gently push in
on tab.
• Cover snaps open. Remove old battery.
Observe polarity markings (+,-) inside
battery compartment.
• Match new battery to polarity markings and
instal new
• Replace battery cover.
NOTE: Use only
2. Attach visor clip Fig. 6-1.
• Slide clip in slot on back of remote control.
– Snap in place.

(CONTACT REVERSE)

*
on floor in center of garage
A23, 12 Volt battery.
A23, 12 Volt battery.
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM
Fig. 7-3
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM
Visor Clip
Model
Number
Battery
Fig. 8-1
Battery
Cover