SECT 10—MAINTENANCE & TROUBLESHOOTING
MONTHLY MAINTENANCE
Door springs and hardware.
• Oil door rollers, bearings, and hinges.
– Use silicone lubricant or light oil.
NOTE: Do not operate door automatically or manually if
springs are broken. CONTACT A PROFESSIONAL FOR
SERVICE.
Balance door.
• Close door.
• Release carriage from rail assembly.
– Pull emergency release knob down.
• Raise door manually about 3 feet.
– Door should stay in that position.
NOTE: If door moves, HAVE DOOR SERVICED BY
A PROFESSIONAL.
• Reattach carriage to rail assembly.
– Pull emergency release knob toward power head.
• Close door
Contact reverse.
• Lay 2" x 4" board flat on the floor in the center of
garage doorway (See page 28).
• Close door using wall button or remote control.
NOTE: If door fails to reverse on contact with board. See
page 28, CONTACT REVERSE. If operator still fails,
replace operator or HAVE THE OPERATOR SERVICED BY
A PROFESSIONAL.
YEARLY MAINTENANCE
Drive Screw
• Lubricate drive screw.
– Use GENIE GLU3 lubricant.
CAUTION
Use only GENIE GLU3 lubricant, because other
lubricants may damage operator.
TROUBLESHOOTING
STB
SELF-DIAGNOSTIC TROUBLESHOOTING
SOURCE ( RED LED ) SENSOR ( GREEN LED ) INDICATED CONDITION
ON
OFF
OFF
2 BLINKS, PAUSE (REPEAT)
2 BLINKS, PAUSE (REPEAT)
3 BLINKS, PAUSE (REPEAT)
4 BLINKS, PAUSE (REPEAT)
NOTE: IF OPERATING PROBLEM EXISTS, THE DOOR CAN BE CLOSED IF YOU: 1. DISCONNECT THE STB SYSTEM FROM THE OPERATOR AND 2. HOLD WALL CONTROL BUTTON
DOWN UNTIL DOOR IS CLOSED. ( REMOTE CONTROL & WIRELESS KEYPAD WILL NOT WORK WITHOUT STB )
CUSTOMER SERVICE: 1.800.354.3643 or www.geniecompany.com
ON
NORMAL OPERATION
1.POWER HEAD NOT POWERED
OFF
2.WIRING FROM POWER HEAD BAD
1.WIRING TO SOURCE MISSING OR BAD
ON
2.POWER HAS BEEN INTERRUPTED
1.BEAM NOT ALIGNED
ON
3.SENSOR DEFECTIVE
1.WIRE TO SENSOR MISSING OR BAD
OFF
2.SENSOR DEFECTIVE
1.SENSOR RECEIVING INTERFERENCE
ON
1.SOURCE NOT SENDING PULSES
ON
2.SOURCE DEFECTIVE
MAINTENANCE CHECK-OFF
YEAR
1
2
3 4 5
6 7 8
9 10 11 12 13 14 15 16 17 18 19 20
MONTH
J
J
J
J
J
J J
J
J J
F
F
F F F
F F F F F F
M M M M M M M M M M M M M M M M M M M M
A A A A A A A A A A A A A A A A A A A A
M M M M M M M M M M M M M M M M M M M M
J
J
J
J
J
J J
J
J J
J
J
J
J
J
J J
J
J J
A A A A A A A A A A A A A A A A A A A A
S S S S S S S S S S S S S S S S S S S S
O O O O O O O O O O O O O O O O O O O O
N N N N N N N N N N N N N N N N N N N N
D D D D D D D D D D D D D D D D D D D D
Just mark the appropriate box each time you
perform routine maintenance.
One less thing you will have to try and
remember on your busy schedule is whether
or not you did the maintenance last month.
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM
REQUIRED ACTION
NONE REQUIRED
1.CHECK BREAKERS, FUSES, PLUGS
2.CHECK WIRING FOR OBVIOUS SHORTS
1.CHECK WIRING
2.REMOVE POWER AND REAPPLY
2. BEAM OBSTRUCTED
1.CHECK ALIGNMENT
3.CALL CUSTOMER SERVICE
1.CHECK WIRING
2.CALL CUSTOMER SERVICE
1.ATTEMPT TO DETERMINE SOURCE OF INTERFERENCE
2.CALL CUSTOMER SERVICE
1.CALL CUSTOMER SERVICE
2.CALL CUSTOMER SERVICE
J
J
J
J
J
J
J
J
J
J
F F F F F
F F F F
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
2. CHECK FOR OBSTRUCTION
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents