CAUTION
New refrigerant air conditioner installation
• This air conditioner adopts the new HFC refrigerant
(R410A) which does not destroy ozone layer.
• The characteristics of R410A refrigerant are; easy to absorb
water, oxidizing membrane or oil, and its pressure is approx.
1.6 times higher than that of refrigerant R22. Accompanied with
the new refrigerant, refrigerating oil has also been changed.
Therefore, do not let water, dust, former refrigerant, or
refrigerating oil enter the refrigerating cycle during installation
work.
• To prevent charging an incorrect refrigerant and refrigerating
oil, the sizes of connecting sections of charging port of the
main unit and installation tools are changed from those for the
conventional refrigerant.
• Accordingly the exclusive tools are required for the new
refrigerant (R410A).
• For connecting pipes, use new and clean piping designed for
R410A, and please care so that water or dust does not enter.
To disconnect the appliance from main power supply.
• This appliance must be connected to the main power supply
by means of a switch with a contact separation of at least
0.1" (3 mm).
The installation fuse (all types can be used) must be used for
the power supply line of this conditioner.
13-EN
� 7 �
2

Accessory parts

 Accessory parts
Part name
Q'ty
Installation Manual
Owner's Manual
Insulation pipe
Installation pattern
Installation templateI
– –
Washer
Eccentric washer
Hose band
Flexible hose
Insulation
Electrical cover 2 holes
 Separate sold parts
• The Ceiling panel and remote controller are sold separately. For the installation of these products, follow the
Installation Manuals supplied with them.
• The wireless type remote controller is designed to be installed by attaching a wireless remote controller kit
(sold separately) to the standard panel. (The wireless remote controller kit consists of a wireless remote controller
and adjust corner caps with a receiver section.)
Shape
Usage
1
This manual
(Hand over to customers)
1
(Hand over to customers)
2
For heat insulation of pipe connecting section
For confirmation of ceiling opening and indoor unit
1
position
For positioning of ceiling position
4
For hanging-down unit
4
For hanging-down unit
1
For connecting drain pipe
1
For adjusting center of drain pipe
1
For heat insulation of drain connecting section
1
For connecting 2 power supply
14-EN