8. E-MAIL BY PC
8.3.4

Restricting access

Specify the IP address of the PC which is to be used to send and receive e-mail.
A PC not specified cannot send e-mail but it can receive e-mail. If no IP address
is specified, all PCs connected to the LAN can send and transmit e-mail.
For example, the IP address of the PC allowed to perform e-mail functions is
172.31.16.5. Then, only that PC on the LAN can send mail.
Cannot
send
mail
Procedure
1. Press [F8] and [2] to show the System Setup menu.
2. Press the [ ] or [ ] key to choose Network Setup and then press the [Enter]
key.
3. Press the [ ] key to choose Mail Gateway and then press the [Enter] key.
4. Choose SMTP Enable IP Address and then press the [Enter] key.
5. Enter IP address of PC which is to send e-mail and then press the [Enter]
key.
6. Press the [Esc] key to show the Update window.
7. Yes is selected; press the [Enter] key to update settings.
8. Press the [Esc] key three times to return to the standby display.
8-8
172.31.16.2
172.31.16.3
PC
PC
Cannot
send
mail
Sent mail is rejected
SMTP Enable IP Address
Send Limit Size (KB)
Attach
Delivery To
Server IP
Address Mode
Mail Address
Auto Delivery Keyword
172.31.16.5
172.31.16.4
PC
Cannot
send
mail
Can send mail
FURUNO
FELCOM 15
172.31.16.1
Mail Gateway
.
.
8
UUENCODE
Server
.
.
FIXED
Mail gateway menu
PC
OK
.
.