Furuno Felcom 15 Operator's Manual page 152

Inmarsat-c mobile earth station
Hide thumbs Also See for Felcom 15:
Table of Contents

Advertisement

6. DISTRESS OPERATIONS
2. Press the [7] key ([6] key when the FELCOM 15 functions as an EGC
receiver) to display the Test menu.
3. Press the [4] key.
4. Press the [Enter] key to start the test. The buzzer sounds repeatedly,
signifying the start of the test mode. Further, the message "Distress buttons
are under test. Cancel the test mode if a real distress alert needs to sent." is
displayed in red.
INF: Distress Buttons entered into TEST MODE.
5. Open the [DISTRESS] button cover.
6. Press the [DISTRESS] button four seconds. The buzzer sounds rapidly for
three seconds and then sounds repeatedly, as in step 4. The message
"Distress Button works correctly." appears if the button is working properly.
7. Close the [DISTRESS] button cover.
8. To escape from the test, press the [Esc] key on the keyboard of the terminal
unit twice. The test mode alarm stops and the message shown below
appears to notifying you that normal operation has been restored.
INF: Distress Buttons returned to NORMAL OPERATION.
9. Press the [Esc] key three times to return to the standby display.
6-6
1. PV Test
2. PV Test Result
3. Self Test
4. Distress Alert Button Test
Test menu
Options
Test
1. Login
Distress Alert Button Test Start
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
3. Self Test
5. Ocean Region
4. Distress Alarm Button Test
6. Test
Distress alert button mode screen
Options
Test
1. Login
Distress Alert Button Test
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
3. Self Test
Distress alert button test mode.
5. Ocean Region
Press any key to escape.
4. Distress Alarm Button Test
6. Test
<Press ESC key to continue>
Distress alert button test
<Press ESC key to continue>
Distress buttons returned to normal state
Test
Yes
No
CAUTION
CAUTION