Keep the fuser oil roll horizontal at all times. Do not tilt it or
lean it against something, as it can cause oil to leak and reduce
print quality.
When removing the photoconductor unit, avoid exposing it
to room light any longer than necessary. The unit contains a
green-colored light-sensitive drum. Exposure to light can
damage the drum, causing dark or light areas to appear on
the printed page and reducing the service life of the drum. If
you need to keep the unit out of the printer for long periods,
cover it with an opaque cloth.
Be sure not to scratch the surface of the drum. When you
remove the photoconductor unit from the printer, always set
the unit on a clean, smooth surface. Also, avoid touching the
drum, since oil from your skin can permanently damage its
surface and may affect print quality.
To get the best print quality, do not store the photoconductor
unit in an area subject to direct sunlight, dust, salty air, or
corrosive gases (such as ammonia). Avoid locations subject to
extreme or rapid changes in temperature or humidity.
Be sure to keep consumable components out of the reach of
children.
Do not leave jammed paper inside the printer. This can cause
the printer to overheat.
3