Intelligent toilet

Advertisement

For Through-
the-Floor
Supplies Only
Install Mounting Blocks and Wax Ring
Position the mounting blocks over the mounting holes.
Secure each of the mounting blocks with two of the supplied lag bolts.
Position a wax ring on the flange.
Connect the Supply Hose to the Toilet
Slide the supply hose outlet into the toilet water inlet.
Slide the clip over the flanges on the supply hose and inlet. Make sure both flanges rest in the gap
in the clip and are firmly held in place.
CAUTION: Risk of property damage. It is critical that the supply hose be firmly secured by the
clip. The supply hose could be displaced when under pressure if the clip is not correctly installed,
resulting in water damage.
IMPORTANT! Confirm the clip is firmly holding the supply hose in place. The clip will be able to rotate freely
with no significant resistance when properly installed.
NOTE:Please use the water supply hose assemblies and tee valve components accompanying with
new machine. The old hose assemblies and tee valve components shall not be used again.
1195109-T01-F
For Wall Supply
Installations Only
Lag Bolt
Flanges
Supply
Hose
Clip
Wax
Ring
14
Hose Should Face
Down When Through
Floor