Mitsubishi Electric Mr. Slim PUHZ-ZRP35VKA Service Manual page 3

Split-type, heat pump air conditioners outdoor unit
Hide thumbs Also See for Mr. Slim PUHZ-ZRP35VKA:
Table of Contents

Advertisement

REFERENCE MANUAL
2
INDOOR UNIT SERVICE MANUAL
Model Name
PLA-ZRP35/50/60/71/125/140BA
PLA-ZRP100BA
PCA-RP35/50/60/71/100/125/140KAQ
PCA-RP71HAQ
PKA-RP35/50HAL
PKA-RP60/71/100KAL
PSA-RP71/100/125/140KA
PEAD-RP35/50/60/71/100/125/140JA(L)Q
SLZ-KA25VAQ3
SLZ-KA35/50VAQ3
SLZ-KA25VAL3
SLZ-KA35/50VAL3
3
SAFETY PRECAUTION
3-1. ALWAYS OBSERVE FOR SAFETY
Before obtaining access to terminal, all supply circuits must be disconnected.
3-2. CAUTIONS RELATED TO NEW REFRIGERANT
Cautions for units utilizing refrigerant R410A
Preparation before the repair service.
• Prepare the proper tools.
• Prepare the proper protectors.
• Provide adequate ventilation.
• After stopping the operation of the air conditioner, turn off
the power-supply beaker.
• Discharge the condenser before the work involving the
electric parts.
Use new refrigerant pipes.
In case of using the existing pipes for R22, be careful with
the following.
· Be sure to clean the pipes and make sure that the insides
of the pipes are clean.
· Change flare nut to the one provided with this product.
Use a newly flared pipe.
· Avoid using thin pipes.
OCH527C
Service Ref.
PLA-ZRP35/50/60/71/125/140BAR1.UK
PLA-ZRP100BAR1
PLA-ZRP100BAR1-ER
PCA-RP35/100/125/140KAQR2
PCA-RP35/100/125/140KAQR2-ER
PCA-RP50/60/71KAQR1
PCA-RP71HAQ
PCA-RP71HAQ-ER
PKA-RP35/50HALR1
PKA-RP35/50HALR1-ER
PKA-RP60/71/100KALR1.TH
PKA-RP60/71/100KALR1.TH-ER
PSA-RP71/100/125/140KA
PEAD-RP35/50/60/71/100/125/140JA(L)QR1.UK
SLZ-KA25VAQ3.TH
SLZ-KA35/50VAQ3.TH
SLZ-KA25VAL3.TH
SLZ-KA35/50VAL3.TH
Precautions during the repair service.
• Do not perform the work involving the electric parts
with wet hands.
• Do not pour water into the electric parts.
• Do not touch the refrigerant.
• Do not touch the hot or cold areas in the refrigerating cycle.
• When the repair or the inspection of the circuit needs to be
done without turning off the power, exercise great caution
not to touch the live parts.
Use a vacuum pump with a reverse flow check
valve.
Vacuum pump oil may flow back into refrigerant cycle and
that can cause deterioration of refrigerant oil, etc.
3
Service
Manual No.
OCH535
OCB535
OCH529
OCB529
OCH491
OCB491
OCH492
OCB492
OCH453
OCB453
OCH452
OCB452
OCH528
OCB528
HWE10090
BWE10160
OCH563
OCB563
OCH564
OCB564

Advertisement

Table of Contents
loading

Table of Contents