Mitsubishi Electric Mr. Slim PUHZ-ZRP35VKA Service Manual page 21

Split-type, heat pump air conditioners outdoor unit
Hide thumbs Also See for Mr. Slim PUHZ-ZRP35VKA:
Table of Contents

Advertisement

PUHZ-ZRP100, 125, 140YKA WIRING DIAGRAM
PUHZ-ZRP100YKAR1
SYMBOL
TB1
Terminal Block <Power Supply>
TB2
Terminal Block <Indoor/Outdoor >
MC
Motor for Compressor
MF1, MF2
Fan Motor
21S4
Solenoid Valve (Four-Way Valve)
63H
High Pressure Switch
TH3, TH33
Thermistor < Outdoor Pipe>
TH4
Thermistor <Discharge
TH6
Thermistor <Outdoor 2-Phase Pipe
TH7
Thermistor <Outdoor
TH8
Thermistor <Heat Sink
TH32
Thermistor <Shell
LEV-A, LEV-B, LEV-C
Electronic Expansion Valve
ACL1~ACL4
Reactor
CY1, CY2
Capacitor
CK
Capacitor
RS
Rush Current Protect Resistor
P.B.
Power Circuit Board
TB-U/V/W
Connection Terminal < U/V/W-Phase>
C. B.
1
MF1
7
MS
3~
1
MF2
7
MS
3~
3
2
1
CNDC
CNS
(WHT)
3
1
TB2
S1
S2
INDOOR
UNIT
S3
TB1
L1
L2
POWER SUPPLY
3N~
400V 50Hz
L3
N
M-NET ADAPTER
SYMBOL
TB7
CN5
CND
CN2M
OCH527C
PUHZ-ZRP125YKAR1
NAME
SYMBOL
TB-L1/L2/L3
TB-N
X52CA/B
N.F.
LI1/LI2/LI3/NI
LO1/LO2/LO3/NO
GD1, GD3
>
CONV.B.
>
L1-A1/IN
L1-A2/OU
>
>
L2-A2/OU
L3-A2/OU
>
N-IN
CK-OU
C.B.
SW1
SW4
SW5
63H
LEV-A
TH33
TH32
TH7 TH6 TH3 TH4
M
t° t°
CNF1
(WHT)
1
3
1
2
1
4
1
2
2 1
1
TH33
TH32
TH7/6
TH3
TH4
LEV-A
(WHT)
(
YLW)
(
BLK)
(
RED)
(
WHT)
(
WHT)
CNF2
(WHT)
1
3
63H
(YLW)
CN2
(WHT)
TRANS
1
7
(PNK)
7
F2
F3
CNAC
(WHT)
1 2
F1
F4
3 4
P. B.
+
V
W
U
MS
3~
MC
N. F.
CNAC1
(WHT)
1
3
LI1
RED
LI2
WHT
LI3
BLK
NI
BLU
GRN/YLW
GD1
NAME
Terminal Block <M-NET connection>
Connector <Transmission>
Connector <Power Supply>
Connector <M-NET communication>
NAME
Connection Terminal < L1/L2/L3-Power Supply>
Connection Terminal
52C Relay
Noise Filter Circuit Board
Connection Terminal < L1/L2/L3/N-Power Supply>
Connection Terminal < L1/L2/L3/N-Power Supply>
Connection Terminal < Ground>
Converter Circuit Board
Connection Terminal < L1-Power Supply>
Connection Terminal < L1-Power Supply>
Connection Terminal < L2-Power Supply>
Connection Terminal < L3-Power Supply>
Connection Terminal
Connection Terminal
Controller Circuit Board
Switch < Manual Defrost, Defect History Record
Reset, Refrigerant Adress>
Switch < Test Operation>
Switch <Function Switch, Model Select>
140 only
LEV-C
M
LEV-B
3
5
M
5
6
1
6
1
3
1
5
LEV-B
CNVMNT
CNMNT
1
6
(RED)
(WHT)
(WHT)
LEV-C
( BLU)
1
CNM
14
(WHT)
CN4
(WHT)
1
2
2
3
1
3
1
SS
21S4
(WHT)
(GRN)
21S4
TH8
3
2
2
7
2
2
2
1
3
1
1
1
7
1
CN2
CN7
CN6
CN5
CN4
(WHT)
(WHT)
(WHT)
(RED)
(WHT)
L3OUT
TB-L3
BLK
BLK
X52CB
WHT
RED
RS
RED
RED
TB-L1
+
X52CA
TB-N
+
+
+
+
+
+
CK
2
CNCT
(RED)
1
2
+
+
1
3
3
1
CNDC
CNL
GD3
(PNK)
(BLU)
2
21
PUHZ-ZRP140YKAR1
SYMBOL
NAME
SW6
Switch < Model Select>
SW7
Switch < Function Setup>
SW8
Switch < Function Setup>
SW9
Switch
SWP
Switch < Pump Down>
CN31
Connector < Emergency Operation>
CN3S
Connector < Connector for Option>
CNDM
Connector < Connection for Option
CN51
Connector <Connection for Option>
SS
Connector <Connection for Option>
CNM
Connector < A-Control Service Inspection Kit>
Connector
CNMNT
< Connect to Optional M-NET Adapter Board>
CNVMNT
Connector
< Connect to Optional M-NET Adapter Board>
LED1,LED2 LED < Operation Inspection Indicators>
F1~F4
FUSE <T6.3AL250V>
X51,X52
Relay
When M-NET adaptor is connected
5
CN5
(WHT)
5
*
*
1
1
1
M-NET ADAPTER
2
CN2M
(WHT)
CN31
1
1
3
1
3
A B S
1
TB7
M-NET
5
*
1. MODEL SELECT
is the switch position
MODEL
SW6
ON
ON
100Y
OFF
OFF
1 2 3 4 5 6 7 8
ON
ON
125Y
OFF
OFF
1 2 3 4 5 6 7 8
ON
ON
140Y
OFF
OFF
1 2 3 4 5 6 7 8
*
2.
SW5 -1 to 5 : Function Switch
3
CONV. B.
3
1
CNAC2
(RED)
1
3
ACL1
LO1
RED
ACL2
LO2
WHT
ACL3
LO3
BLK
NO
BLU
ACL4
(Contact Input)
>
CND
(WHT)
3
1
3
*
SW5-6
2
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6