Special Notice Of Product; Disposal Requirements - Daikin LREQ15B7Y1R Installation Manual

Air cooled refrigeration condensing unit
Table of Contents

Advertisement

CAUTION
• Carry out drain piping properly following this installation manual
and insulate the pipe to prevent condensation.
Improper drain piping may result in indoor water leakage and
property damage.
• Install the indoor and outdoor units, power cord and connecting
wires at least 1 meter away from televisions or radios to prevent
picture interference and noise.
(Depending on the incoming signal strength, a distance of 1 meter
may not be sufficient to eliminate noise.)
• Do not install the condensing unit in the following locations:
1. Where there is a high concentration of mineral oil spray or
vapour (e.g. a kitchen).
Plastic parts may deteriorate and cause parts to fall off or water
to leak.
2. Where corrosive gas, such as sulphurous acid gas, is produced.
Corrosion of copper pipes or brazed parts may occur and cause
refrigerant leakage.
3. Where there is a machine that generates electromagnetic wave
and where voltage fluctuation often occurs such as a factory.
Control system may malfunction and as a result the unit may
not properly operate.
4. Where flammable gas may leak, where carbon fibre or ignitable
dust is suspensions in the air, or where volatile flammables
such as paint thinner or gasoline are handled.
Operating the unit in such conditions may result in fire.
5. Vehicles, ships, or other places that generate vibration or cause
the condensing unit to move.
The condensing unit may malfunction or cause oxygen
deficiency accidents as a result of refrigerant leakage.
6. Places with excessive voltage fluctuations.
The condensing unit may malfunction.
7. Places where fallen leaves accumulate or weeds grow thick.
8. Places that become small animals' shelter.
Small animals coming in contact with electrical parts can cause
malfunctions, smoke, or ignition.
• The condensing unit is not intended for use in a potentially
explosive atmosphere.

1-2 Special notice of product

This condensing unit comes under the term "appliances not
accessible to the general public".
[CLASSIFICATION]
This condensing unit comes under the term "appliances not
accessible to the general public".
Refer to the connected indoor unit to know the climate class
(EN60335-2-89).
[EMC CHARACTERISTICS]
This system is a class A product. In a domestic environment this
product may cause radio interference in which case the user may be
required to take adequate measures.
[REFRIGERANT]
This System use R410A refrigerant.
The total maximum refrigerant charge of a Multi-ZEAS system must
be less than 100 kg, this to be in accordance with CE requirements
(EN603350-2-40 standard). This means that in case the calculated
total refrigerant charge is equal to or more than 95 kg you must divide
your multiple outdoor system into smaller independent systems, each
containing less than 95 kg refrigerant charge.
CAUTION
This unit is already filled with a certain amount of R410A.
Never open liquid and gas shutoff valve until the step specified in
"9. CHECKS AFTER WORK COMPLETION" on page
• The refrigerant R410A requires that strict precautions be observed
for keeping the system clean, dry and tightly sealed.
Read the chapter
"6. REFRIGERANT PIPING" on page 6
and follow these procedures correctly.
LREQ15+20B7Y1R
Air cooled refrigeration condensing unit
4P360438-1B – 2014.01
A.Clean and dry
Strict measures must be taken to keep impurities (including
SUNISO oil and other mineral oils as well as moisture) out of the
system.
B.Tightly sealed
Take care to keep the system tight when installing.
R410A contains no chlorine, does not destroy the ozone layer
and so does not reduce the earth's protection against harmful
ultraviolet radiation. R410A will contribute only slightly to the
greenhouse effect if released into the atmosphere.
• Since R410A is a mixed refrigerant, the required additional
refrigerant must be charged in its liquid state. If the refrigerant is
charged in a state of gas, its composition changes and the system
will not work properly.
• Be sure to perform refrigerant replenishment.
Refer to
and the label of instructions on refrigerant replenishment on the
cover surface of the control box,
Important information regarding the refrigerant used
This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol. Do not vent gases into the atmosphere.
Refrigerant type : R410A
(1)
GWP
(1)
GWP = global warming potential
Please fill in with indelible ink,
the factory refrigerant charge of the product,
the additional refrigerant amount charged in the field and
+
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product
charging port (e.g. onto the inside of the service cover).
6
[REFRIGERANT OIL]
This system uses DAPHNE FVC68D refrigerant oil. The label below is
attached to the outdoor unit, under the refrigerant label. Fill in the
blanks with indelible ink.
R E F . O I L V O L U M E
REF. OIL: DAPHNE FVC68D
TARGET EVAPORATING TEMP.=
1
Target evaporating temperature
2
Total amount of required refrigerant oil
3
Amount of additional refrigerant oil
[DESIGN PRESSURE]
Since design pressure is 3.8 MPa or 38 bar (for R407C units :
3.3 MPa or 33 bar), the wall thickness of pipes should be more
18.
carefully selected in accordance with the relevant local and national
regulations.

1-3 Disposal requirements

carefully
Dismantling of the unit, treatment of the refrigerant, of oil and of other
parts must be done in accordance with relevant local and national
legislation.
"9. CHECKS AFTER WORK COMPLETION" on page 18
value : 1975
the total refrigerant charge
5
°c
TOTAL REQUIRED.=
L
ADDITIONAL OIL.=
L
4
1 factory refrigerant charge
of the product : see unit
name plate
1
2 additional refrigerant
2
amount charged in the field
3 total refrigerant charge
4 Contains fluorinated
3
greenhouse gases covered
by the Kyoto Protocol
5 outdoor unit
6 refrigerant cylinder and
manifold for charging
1
2
3
Installation manual
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lreq20b7y1rLreq15Lreq20Lreq-by1r

Table of Contents