General Information - Napoleon GS50N Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

2.3

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!
Altitude (FT)
Max. Input (BTU/HR)
Max. Output Steady State (BTU/HR)
Efficiency (w/the fan on)
Maximum A.F.U.E.
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow
Conditions)
For elevations between 2,000ft (610m) and 4,500ft (1372m) above sea level, this appliance must be
de-rated by 10% using the certified high altitude kit. When the appliance is installed at elevations above
4,500ft (1372mm), and in the absence of specific recommendations from the local authority having
jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional
1,000ft (305m).
Change in flame appearance from "HI" to "LO" is more evident in natural gas than in propane. Expansion /
contraction noises during heating up and cooling down cycles are normal and to be expected.
GDS50: This appliance is approved for bathroom, bedroom and
bed-sitting room installations and is suitable for mobile homes. The
natural gas model is suitable for installation in a mobile home that is
permanently positioned on its site and fueled with natural gas.
GS50: This appliance is approved for bedroom and bed-sitting room
installations.
GS50
NG
0-2000
0-2000
44,000
40,000
31,200
30,000
77%
78%
65%
67%
4.5" (11mb)
11" (27mb)
Water Column
Water Column
7" (17mb)
13" (330.2mm)
Water Column
Water Column
3.5" (9mb)
10" (25mb)
Water Column
Water Column
GDS50
P
NG
0-2000
44,000
37,000
84%
77%
4.5" (11mb)
Water Column
7" (17mb)
Water Column
3.5" (9mb)
Water Column
7
EN
P
0-2000
40,000
34,400
86%
79%
11" (27mb)
Water Column
13" (330.2mm)
Water Column
10" (25mb)
Water Column
W415-1427 / A / 09.27.17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents