Process pressure measurement pressure transmitter with ceramic and metal sensors; modular design and easy operation; with analog or hart electronics (84 pages)
Process pressure measurement pressure transmitter with ceramic and metal sensors overload-resistant and function-monitored with analog, hart or profibus pa electronics (84 pages)
Summary of Contents for Endress+Hauser Cerabar M PMC51
Page 1
Products Solutions Services XA02712P-A/00/EN/ 01.21 71544760 2021-10-11 Safety Instructions Cerabar M PMC51, PMP51, PMP55 4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus II 1/2 D Ex ta/tb IIIC Da/Db...
BA00384P/00 Supplementary Explosion-protection brochure: CP00021Z/11 documentation The Explosion-protection brochure is available: • In the download area of the Endress+Hauser website: www.endress.com -> Downloads -> Brochures and Catalogs -> Text Search: CP00021Z • On the CD for devices with CD-based documentation Manufacturer's UK Declaration of Conformity...
Cerabar M PMC51, PMP51, PMP55 XA02712P-A Other standards Among other things, the following standards shall be observed in their current version for proper installation: • IEC/EN 60079-14: "Explosive atmospheres - Part 14: Electrical installations design, selection and erection" • EN 1127-1: "Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology"...
Page 6
XA02712P-A Cerabar M PMC51, PMP51, PMP55 Extended order code: Cerabar M The following specifications reproduce an extract from the product structure and are used to assign: • This documentation to the device (using the extended order code on the nameplate).
Cerabar M PMC51, PMP51, PMP55 XA02712P-A Safety • The device is intended to be used in explosive atmospheres as defined in the scope of IEC 60079-0 or equivalent national standards. If no instructions: potentially explosive atmospheres are present or if additional...
XA02712P-A Cerabar M PMC51, PMP51, PMP55 Safety instructions: Installation A0023750 Electronic; Zone 21 Process; Zone 20 Power supply PMC51, PMP51, PMP55 • Do not open in a potentially explosive dust atmosphere. • Seal the cable entry or piping tight (see protection type of enclosure in the "Temperature tables"...
Cerabar M PMC51, PMP51, PMP55 XA02712P-A Temperature • The specified surface temperature takes into account all direct heat influences from process heat and self-heating at the tables enclosure. • Surface temperatures at the process side maybe higher and must be considered by the user (e.g. at high temperature process connections).
XA02712P-A Cerabar M PMC51, PMP51, PMP55 Device type PMP51, PMP55 Maximum surface Process temperature range Ambient temperature range temperature T125 °C –40 °C ≤ T ≤ +80 °C –40 °C ≤ T ≤ +60 °C –40 °C ≤ T ≤ +100 °C –40 °C ≤...
Page 11
Cerabar M PMC51, PMP51, PMP55 XA02712P-A Cable entry: Connection compartment Ex tb Thread Clamping range Material Sealing insert O-ring M20x1,5 ø 8 to 10.5 mm Ms, nickel-plated Silicone EPDM (ø 17x2) ø 6.5 to 13 mm Standard Separate clamping inserts available •...