Endress+Hauser Cerabar M PMP51 Technical Information

Process pressure measurement pressure transmitter with ceramic and metal sensors; modular design and easy operation; with analog or hart electronics
Hide thumbs Also See for Cerabar M PMP51:
Table of Contents

Advertisement

Quick Links

Technical Information
Cerabar M PMC51, PMP51, PMP55
Process pressure measurement
Pressure transmitter with ceramic and metal sensors;
Modular design and easy operation;
With analog or HART electronics
Application
The Cerabar M pressure transmitter is used for the
following measuring tasks:
• Absolute pressure and gauge pressure measurement in
gases, steams or liquids in all areas of process
engineering and process measurement technology
• Level, volume or mass measurements in liquids
• High process temperature
– without diaphragm seals up to 125°C (257°F)
– with diaphragm seals up to 400°C (752°F)
• High pressure up to 400 bar (6000 psi)
• International usage thanks to a wide range of approvals
TI436P/00/EN/02.10
No. 71109889
Your benefits
• Very good reproducibility and long-term stability
• High reference accuracy: up to 0.15%,
as PLATINUM version: 0.075%
• Turn down up to 100:1
• End-to-end modularity for differential pressure,
hydrostatics and pressure (Deltabar M – Deltapilot M –
Cerabar M), e.g.
– replaceable display
– universal electronics
• Easy commissioning without the need for an operating
tool
• Menu-guided operation
• Output signals: 4 to 20 mA, 4 to 20 mA with HART

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Cerabar M PMP51

  • Page 1 Technical Information Cerabar M PMC51, PMP51, PMP55 Process pressure measurement Pressure transmitter with ceramic and metal sensors; Modular design and easy operation; With analog or HART electronics Application Your benefits The Cerabar M pressure transmitter is used for the • Very good reproducibility and long-term stability •...
  • Page 2: Table Of Contents

    PMP55 ......... . . 18 Standards and guidelines ......62 Endress+Hauser...
  • Page 3 Pressure ......... . . 83 Endress+Hauser...
  • Page 4: Function And System Design

    – Gas-tight, elastomer-free – Process connections with minimum remove paint-wetting substances, for use oil volume in paint shops – Completely welded versions OPL = over pressure limit; depends on the lowest-rated element, with regard to pressure, of the selected components Endress+Hauser...
  • Page 5: Measuring Principle

    Advantages: • Depending on the version, can be used for process pressure up to 400 bar (6000 psi) and simultaneous extreme process temperatures • High long-term stability • Guaranteed overload resistance up to 4 times the nominal pressure Endress+Hauser...
  • Page 6: Level Measurement (Level, Volume And Mass)

    • 4 to 20 mA with HART communication protocol The device can be fitted with a tag name and a preset bus address, see  ä 63 ff "Ordering information" System integration (except analog electronics) feature 895 "Identification:" version "Z1" and "Z2". Endress+Hauser...
  • Page 7: Input

    For the appropriate standards and other information, see  ä 25, "Pressure specifications" section. OPL: over pressure limit depends on the lowest-rated element, with regard to pressure, of the selected components Version in the order code see also  ä 63 ff, feature 70 "Sensor range" Endress+Hauser...
  • Page 8 The vacuum resistance applies to the measuring cell at reference conditions. The pressure and temperature application limits of the selected filling oil must also be observed for the PMP55.  ä 59, "Diaphragm seal filling oils" section. Version in the order code  ä 63 ff, feature 70 "Sensor range" Endress+Hauser...
  • Page 9: Explanation Of Terms

    Example: 1 bar (15 psi) measuring cell Set span Span based on zero point Nominal value i upper range limit (URL) Nominal measuring range Sensor measuring range Lower range limit Upper range limit Lower range value Upper range value Endress+Hauser...
  • Page 10: Output

    • Current output: 1 A Resolution • Display HART: can be set (factory setting: presentation of the maximum accuracy of the transmitter) Dead time, Time constant (T63) 100 % 90 % 63 % P01-xxxxxxxx-05-xx-xx-xx-036 Presentation of the dead time and the time constant Endress+Hauser...
  • Page 11: Dynamic Behavior: 4 To 20 Ma (Analog Electronics)

    • HART: via DIP switch on the electronic insert, switch position "on" = value set in the software (factory setting: 2 s) and "off". Via local display, handheld terminal or PC with operating program, continuous from 0 to 999 s Endress+Hauser...
  • Page 12: Power Supply

    Test terminals, see "Taking 4 to 20 mA test signal" section Minimum supply voltage = 11.5 V DC Taking 4 to 20 mA test signal A 4 to 20 mA test signal may be measured via the test terminals without interrupting the measurement. Endress+Hauser...
  • Page 13 Left: electrical connection for devices with an M12 connector Right: view of the connector at the device Endress+Hauser offers the following accessories for devices with an M12 connector: Plug-in jack M 12x1, straight • Material: body PA; coupling nut CuZn, nickel-plated •...
  • Page 14: Supply Voltage

     ä 63 ff, feature 50 "Electrical connection". Cable entry Cable specification • Endress+Hauser recommends using twisted, shielded two-wire cables. • Terminals for wire cross-sections 0.5 to 2.5 mm (20 to 14 AWG) • Cable outer diameter: 5 to 9 mm (0.2 to 0.35 in) No influence on 4 to 20 mA signal up to 5 % residual ripple within the permitted voltage range [according to...
  • Page 15: Performance Characteristics - General

    Position-dependent zero point shift can be corrected at the device.  ä 19, "General installation instructions" section and  ä 60 ff, "Installation instructions" section. Warm-up period • 4 to 20 mA analog: <1.5 s • 4 to 20 mA HART: <5 s Endress+Hauser...
  • Page 16: Performance Characteristics - Ceramic Process Isolating Diaphragm

    100 mbar (1.5 psi), 250 mbar (4 psi), 400 mbar (6 psi) 1 bar (15 psi), 2 bar (30 psi), 4 bar (60 psi), 10 bar (0.32 + 0.1 x TD) (0.36 + 0.2 x TD) (150 psi), 40 bar (600 psi) Endress+Hauser...
  • Page 17: Performance Characteristics - Metal Process Isolating

    The total error comprises the long-term stability and the total performance. All specifications apply to the temperature range –10 to +60°C (+14 to +140°F) and Turndown 1:1. Measuring cell % of URL/year 400 mbar (6 psi) ±0.44 1 bar to 100 bar (15 psi to 1500 psi) ±0.35 400 bar (6000 psi) ±0.5 Endress+Hauser...
  • Page 18: Thermal Change In The Zero Output And The Output Span - Pmp51 And Pmp55

    2 bar (30 psi), 4 bar (60 psi), 10 bar ±(0.34 + 0.15 x TD) ±(0.4 + 0.25 x TD) (150 psi), 40 bar (600 psi), 100 bar (1500 psi) 400 bar (6000 psi) ±(0.3 + 0.35 x TD) ±(0.3 + 0.7 x TD) Endress+Hauser...
  • Page 19: Operating Conditions (Installation)

    In hazardous areas, comply strictly with the safety instructions when the housing cover is closed and open. • Endress+Hauser offers a mounting bracket for installing the device on pipes or walls. See also  ä 19, "Wall and pipe mounting" section.
  • Page 20: Separate Housing" Version

    • Intrinsically safe installations (Ex ia/IS) • FM/CSA IS: for Div.1 installation only Reduction in installation height If the separate housing is used, the mounting height of the process connection is reduced compared to the dimensions of the standard version (see graphic). Endress+Hauser...
  • Page 21: Oxygen Applications

     ä 66 feature 570 "Service", version "HC". Ultrapure gas applications Endress+Hauser also provides devices which have been cleaned of oil and grease for special applications, such as for ultrapure gas. No special restrictions regarding the process conditions apply to these devices.
  • Page 22: Operating Conditions (Environment)

    For high-temperature applications, either a PMP55 with a temperature isolator or with a capillary can be used. If vibrations also occur in the application, Endress+Hauser recommends you use a PMP55 with a capillary. If a PMP55 with a temperature isolator or capillary is used, we recommend a suitable bracket for mounting (see "Wall and pipe mounting"...
  • Page 23: Vibration Resistance

    The device is connected as illustrated in the following graphic. For details refer to TI103R/09/EN, XA036R/09/A3 and KA161R/09/A6. Wiring Incoming connection cables Unit to be ➀ protected ➁ Black Connection cables HAW569Z Shield grounding ➀ without ➁ direct P01-xMx5xxxx-04-xx-xx-en-006 Endress+Hauser...
  • Page 24: Operating Conditions (Process)

    Extreme jumps in temperature can result in temporary measuring errors. Temperature compensation takes effect after several minutes. Internal temperature compensation is faster the smaller the jump in temperature and the longer the time interval involved. For further information please contact your local Endress+Hauser Sales Center. PMP51 (with metal process isolating diaphragm) Description...
  • Page 25: Pressure Specifications

    EN 1092-1 Tab. 18. The chemical composition of the two materials can be identical. The equation does not apply for PMP51 and PMP55 with a 40 bar (600 psi) - or a 100 bar (1500 psi) - measuring cell. Endress+Hauser...
  • Page 26: Mechanical Construction

    Thread ISO 228 G 1/2 A G 1/4 (female); Material version GLJ: AISI 316L, version GLC: Alloy C276; weight: 0.63 kg(1.39 lbs) Thread ISO 228 G 1/2 A hole 11.4 mm (0.45 in); Material version GMJ: AISI 316L, version GMC: Alloy C276; weight: 0.63 kg(1.39 lbs) Endress+Hauser...
  • Page 27 Version GOJ: thread JIS B0203 R 1/2 (male), material: AISI 316L; Weight: 0.63 kg (1.39 lbs) Installation height H for devices with threaded connection and internal process isolating diaphragm F31 housing F15 housing 154 mm (6.06 in) 146 mm (5.75 in) Endress+Hauser...
  • Page 28 Thread DIN 13 M 44x1.25; Material version G4J: AISI 316L; weight: 0.63 kg (1.39 lbs) Installation height H for devices with threaded connection and flush-mounted process isolating diaphragm F31 housing F15 housing 201 mm (7.91 in) 193 mm (7.6 in) Endress+Hauser...
  • Page 29 Designation as per DIN 2527 in brackets Housing weight  ä 52 OPL.: 15 bar (225 psi) Process temperature range: –10 to +60 °C (+14 to +140 °F) ECTFE coating on AISI 316L/1.4435. When operating in hazardous areas, avoid electrostatic charging of the plastic surfaces. Endress+Hauser...
  • Page 30 Combination of AISI 316 for required pressure resistance and AISI 316L for required chemical resistance (dual rated) ECTFE coating on AISI 316L/1.4435. When operating in hazardous areas, avoid electrostatic charging of the plastic surfaces. OPL.: 15 bar (225 psi) Process temperature range: –10 to +60 °C (+14 to +140 °F) Endress+Hauser...
  • Page 31 [mm] [kg] 50 A 10 K 80 A 10 K 100 A 10 K Housing weight, see  ä 52 Installation height H for devices with flange F31 housing F15 housing 201 mm (7.91 in) 193 mm (7.6 in) Endress+Hauser...
  • Page 32: Process Connections Pmp51 (With Metal Process Isolating Diaphragm)

    Material version R1J: AISI 316L, version R1C: Alloy C276/2.4819; Weight: 0.7 kg (1.54 lbs) Installation height H for devices with threaded connection and internal process isolating diaphragm F31 housing F15 housing Height H 169 mm (6.65 in) 150 mm (5.91 in) Endress+Hauser...
  • Page 33 Material version G1J: AISI 316L; weight 0.4 kg (0.88 lbs) – Einschweißadapter Bestell-Nr.: 52002643 SW27 G ½ Viton-Dichtung G ½ ø26 ø50 max. Druckfestigkeit 100 bar O-Ring 14 x 1,78 Viton oder NBR P01-PMx5xxxx-06-xx-xx-en-003 Version G0J: Thread ISO 228 G1/2; weight: 0.4 kg (0.88 lbs) Endress+Hauser...
  • Page 34 162 mm (6.38 in) 147 mm (5.79 in) 1 1/2 MNPT 169 mm (6.65 in) 150 mm (5.91 in) 2 MNPT 199 mm (7.83 in) 144 mm (5.67 in) M 20x1.5 163 mm (6.42 in) 148 mm (5.83 in) Endress+Hauser...
  • Page 35 Housing weight  ä 52 With these process connections the sealing surface is smaller than described in the standard. Due to a smaller sealing surface a special seal must be used. Contact a seal manufacturer or your local Endress+Hauser Sales Center. Endress+Hauser...
  • Page 36 With these process connections the sealing surface is smaller than described in the standard. Due to a smaller sealing surface a special seal must be used. Contact a seal manufacturer or your local Endress+Hauser Sales Center. Height H for devices with flange...
  • Page 37: Pmp55 Basic Device

    175 mm (6.89 in) PMP55 basic device ➀ ➁ P01-PMP75xxx-06-09-xx-xx-012 PMP55 basic device with diaphragm seal PMP55 basic device Diaphragm seal, here e.g. flange diaphragm seal F31 housing F15 housing Height H 190 mm (7.48 in) 175 mm (6.89 in) Endress+Hauser...
  • Page 38: Process Connections Pmp55 (With Diaphragm Seal)

    • When using high-temperature oils the design can deviate significantly. • Observe the information in the "Planning instructions for diaphragm seal systems" section  ä 58 ff. • For further information please contact your local Endress+Hauser Sales Center. Thread, flush-mounted process isolating diaphragm...
  • Page 39 DIN11851 D [in] G [mm] h [mm] L [mm] [kg] DN 25 PN40 Rd 52 x 1/6 DN 32 PN40 Rd 58 x 1/6 DN 40 PN40 Rd 65 x 1/6 DN 50 PN25 Rd 78 x 1/6 Endress+Hauser...
  • Page 40 (31.5 in) as standard. Lower surface roughness, see feature 570 "Service" version HK. Threaded adapter Diaphragm seal Version Nominal Nominal Diameter Thread Max. diaphragm Weight diameter pressure diameter Diaphragm seal [mm] [mm] [kg] DN 40 Rd 65 x 1/6 PN 16 DN 50 Rd 78 x 1/6 Endress+Hauser...
  • Page 41 DN 51 DN 50 DN 76.1 – Diaphragm seal versions optionally in conformity with ASME-BPE for use in biochemical processes, wetted surfaces 0.38 m (15 in), electropolished; to be ordered using feature 570 "Service", version "HK" in the order code. Endress+Hauser...
  • Page 42  0.8 m (31.5 in) as Process connection PMP55, surface roughness of the surfaces in contact with the medium R standard. Lower surface roughness, see feature 570 "Service" version HK. Version Material Nominal Diaphragm pressure seal weight [kg] AISI 316L PN 25 0.75 Endress+Hauser...
  • Page 43 [in] [bar] [mm] [mm] [mm] [mm] [mm] [kg] PN 40 1 13/16 – 1/8" 22 42.6 0.45 1 1/2 PN 40 2 5/16 – 1/8" 42.6 0.75 PN 40 2 7/8 – 1/8" 42.6 Endress+Hauser...
  • Page 44 Rd 58 x 1/6" DN 40 PN 40 Rd 65 x 1/6" DN 50 PN 25 68.5 Rd 78 x 1/6" DN 65 PN 25 Rd 95 x 1/6" DN 80 PN 25 Rd 110 x 1/4" 30 2.55 Endress+Hauser...
  • Page 45 Threaded adapter Diaphragm seal Version Nominal Nomi- Diame- Hole Diameter Diame- Height Max. dia- Dia- diameter circle phragm phragm pres- diame- diameter seal sure weight [mm] [mm] [mm] [mm] [mm] [mm] [kg] 4 x  9 DN 50 PN 16 Endress+Hauser...
  • Page 46 [mm] [mm] [kg] DN 50 PN 10-40 50 / 100 / 200 48.3 3.2 / 3.8 / 4.4 DN 80 PN 10-40 50 /100 / 200 6.2 / 6.7 / 7.8 Endress+Hauser...
  • Page 47 7.5 / 0.94 / 5 / 127 0.75 / 19.1 6 / 3.50 / 89 316L 190.5 23.9 152.4 AISI 316/ 8.25 / 1.12 / 5 / 127 0.75 / 19.1 6 / 3.50 / 89 316L 209.5 28.4 152.4 Endress+Hauser...
  • Page 48 8 / 203.2 2 / 50.8 3.7 / 94 4 / 101.6 6 / 152.4 11.2 8 / 203.2 12.4 2 / 50.8 3.7 / 94 13.1 4 / 101.6 14.4 6 / 152.4 15.7 8 / 203.2 16.9 Endress+Hauser...
  • Page 49 The roughness of the surface in contact with the medium, including the raised face of the flanges (all standards) made of Hastelloy C, Monel or tantalum, is Ra 0.8 m. Lower surface roughness available on request. Housing weight  ä 52 Endress+Hauser...
  • Page 50 1 NPT ø30 SW 36 36 AF ø52 P01-PMP75xxx-06-09-xx-xx-008 Process connection PMP55, version "UGJ" and "UHJ", threaded, material AISI 316L, seal Viton Version Description Nominal Diaphragm seal weight pressure [kg] 1/2 NPT PN 250 4.75 1 NPT PN 250 Endress+Hauser...
  • Page 51 Process connection PMP55, version "UBJ" and "UCJ", threaded, with integrated seal lip, material AISI 316L Version Measuring range Description Nominal Diaphragm seal weight pressure [kg] > 40 bar ISO 228 G 1/2 A PN 400 4.75 > 40 bar ANSI 1/2 MNPT PN 400 4.75 Endress+Hauser...
  • Page 52: Wall And Pipe Mounting With Mounting Bracket

    • F31 housing, optionally: – Die-cast aluminum with protective powder-coating on polyester base: RAL 5012 (blue), cover: RAL 7035 (gray) • Sight glass: mineral glass • Cable gland M20 x 1.5: polyamide (PA) or CuZn nickel-plated • Pressure compensation filter: PA6 GF10 Endress+Hauser...
  • Page 53 • Mounting accessories: mounting kit with screws AISI 304 • Diaphragm seal capillary: AISI 316 Ti • Protective hose for diaphragm seal capillary: AISI 304 For process connections, process isolating diaphragms, seals and filling oils see ordering information,  ä 63 ff. Endress+Hauser...
  • Page 54: Human Interface

    • Comprehensive diagnostic functions (fault and warning message etc.) Measured value display Device tag Value Header line Symbol Main line Unit Information line – Bargraph Operating menu Operating keys Parameter with selection list Direct Access Selection Code options Freely editable parameter Value that can be edited P01-Mxxxxxxx-07-xx-xx-en-002 Endress+Hauser...
  • Page 55 Slot for optional local display (3.6 mA) DIP switch for switching damping on/off DIP switch only for Deltabar M Slot for optional local display Green LED to indicate successful operation Operating keys for lower range value (zero) and upper range value (span) Endress+Hauser...
  • Page 56: Onsite Operation

    Setting lower range value and upper range value - reference pressure present at the device Device reset Locking and unlocking parameters relevant to the measured value Value acceptance indicated by the green LED Switching damping on and off Endress+Hauser...
  • Page 57: Remote Operation

    • Field Communicator 375 handheld terminal. Use the handheld terminal to set all parameters all along the bus cable via menu operation. • Field Xpert: Field Xpert is an industrial PDA with integrated 3.5" touchscreen from Endress+Hauser based on Windows Mobile. It communicates via wireless with the optional VIATOR Bluetooth modem connected to a HART device point-to-point or wireless via WiFi and Endress+Hauser’s Fieldgate FXA520.
  • Page 58: Planning Instructions For Diaphragm Seal Systems

    To help you select suitable diaphragm seal systems for your individual application, Endress+Hauser provides a free "Applicator Sizing Diaphragm Seal" selection tool. This tool is available for download online at "www.endress.com/applicator", or is available offline on a CD. For further details, or for information on an optimum diaphragm seal solution, please contact your local Endress+Hauser Sales Center.
  • Page 59: Diaphragm Seal Filling Oils

    Observe temperature limits of the device ( ä 24) and of the system ( ä 58). When simultaneously applying the diaphragms seal at high process temperatures and low absolute pressures, Endress+Hauser recommends the vacuum service (Feature 570 "Service" version "HG").
  • Page 60: Installation Instructions

    Cerabar M PMC51, PMP51, PMP55 Installation instructions Diaphragm seal systems • Endress+Hauser offer flushing rings as accessory to clean process isolating diaphragms without taking the transmitters out of process. For further information please contact your local Endress+Hauser Sales Center. • A diaphragm seal together with the transmitter form a closed, calibrated system, which is filled through openings in the diaphragm seal and in the transmitter's measurement system.
  • Page 61 260 °C (+500 °F). For the temperature application limits, see  ä 59, "Diaphragm seal filling oils" section. To minimize the influence of rising heat, Endress+Hauser recommends the device be mounted horizontally or with the housing pointing downwards.
  • Page 62: Certificates And Approvals

    Cerabar M PMC51, PMP51, PMP55 Certificates and approvals CE mark The device meets the legal requirements of the relevant EC directives. Endress+Hauser confirms that the device has been successfully tested by applying the CE mark. Ex approvals • ATEX • IECEx •...
  • Page 63: Ordering Information

    Thread M20, IP66/68 NEMA4X/6P Thread G1/2, IP66/68 NEMA4X/6P Thread NPT1/2, IP66/68 NEMA4X/6P Connector M12, IP66/68, NEMA4X/6P Connector 7/8", IP66/68, NEMA4X/6P Connector Han7D, 90deg, IP65 Cable 5m, IP66/68 NEMA4X/6P + pressure compensation via cable Valve connector ISO4400 M16, IP64 Special version Endress+Hauser...
  • Page 64: Pmc51 (Continued)

    Special version Reference accuracy: Platinum Standard Special version Calibration; Unit: Sensor range; % Sensor range; mbar/bar Sensor range; kPa/MPa Sensor range; mm/mH2O Sensor range; inH2O/ftH2O Sensor range; psi Customized pressure; see additional spec. Customized level; see additional spec. Special version Endress+Hauser...
  • Page 65: Pmc51 (Continued)

    Thread ANSI MNPT1-1/2, 316L, flush-mounted Thread ANSI MNPT2, 316L, flush-mounted Special version Seal: FKM Viton FKM Viton, FDA HNBR, FDA, 3A Class II, KTW, AFNOR, BAM EPDM EPDM, FDA, 3A Class II, USP Class VI, DVGW, KTW, W270, WRAS, ACS, NSF61 Special version Endress+Hauser...
  • Page 66: Pmc51 (Continued)

    Welding neck G1-1/2, 316L Welding neck G1-1/2, 316L, 3.1, EN10204-3.1 material, inspection certificate Weld-in tool adapter G1-1/2, brass Plug-in jack M12 Plug-in jack M12, 90deg Plug-in jack M12, 90deg+5m cable Software version: 01.00.zz, HART, DevRev01 Identification: Measuring point (TAG) Bus address Endress+Hauser...
  • Page 67: Pmp51

    Thread M20, IP66/68 NEMA4X/6P Thread G1/2, IP66/68 NEMA4X/6P Thread NPT1/2, IP66/68 NEMA4X/6P Connector M12, IP66/68, NEMA4X/6P Connector 7/8", IP66/68, NEMA4X/6P Connector Han7D, 90deg, IP65 Cable 5m, IP66/68 NEMA4X/6P + pressure compensation via cable Valve connector ISO4400 M16, IP64 Special version Endress+Hauser...
  • Page 68: Pmp51 (Continued)

    Special version Reference accuracy: Platinum Standard Special version Calibration; Unit: Sensor range; % Sensor range; mbar/bar Sensor range; kPa/MPa Sensor range; mm/mH2O Sensor range; inH2O/ftH2O Sensor range; psi Customized pressure; see additional spec. Customized level; see additional spec. Special version Endress+Hauser...
  • Page 69: Pmp51 (Continued)

    Prepared for diaphragm seal mount, 316L Special version Material of the process isolating diaphragm: 316L AlloyC Rhodium>gold>316L Special version Fill fluid: Silicone oil Inert oil Special version Additional ordering information (optional) Operating language: English German French Spanish Italian Dutch Chinese Japanese Endress+Hauser...
  • Page 70: Pmp51 (Continued)

    Welding neck G1-1/2, 316L Welding neck G1-1/2, 316L, 3.1, EN10204-3.1 material, inspection certificate Weld-in tool adapter G1-1/2, brass Plug-in jack M12 Plug-in jack M12, 90deg Plug-in jack M12, 90deg+5m cable Software version: 01.00.zz, HART, DevRev01 Identification: Measuring point (TAG) Bus address Endress+Hauser...
  • Page 71: Pmp55

    Thread M20, IP66/68 NEMA4X/6P Thread G1/2, IP66/68 NEMA4X/6P Thread NPT1/2, IP66/68 NEMA4X/6P Connector M12, IP66/68, NEMA4X/6P Connector 7/8", IP66/68, NEMA4X/6P Connector Han7D, 90deg, IP65 Cable 5m, IP66/68 NEMA4X/6P + pressure compensation via cable Valve connector ISO4400 M16, IP64 Special version Endress+Hauser...
  • Page 72: Pmp55 (Continued)

    Special version Reference accuracy: Platinum Standard Special version Calibration; Unit: Sensor range; % Sensor range; mbar/bar Sensor range; kPa/MPa Sensor range; mm/mH2O Sensor range; inH2O/ftH2O Sensor range; psi Customized pressure; see additional spec. Customized level; see additional spec. Special version Endress+Hauser...
  • Page 73: Pmp55 (Continued)

    Thread FNPT1/2, PN250, 316L, separator, threaded Thread FNPT1, PN250, 316L, separator, threaded Thread ANSI MNPT1, AlloyC, flush-mounted Thread ANSI MNPT1, 316L, flush-mounted Thread ANSI MNPT1-1/2, AlloyC, fm=flush-mounted Thread ANSI MNPT1-1/2, 316L, flush-mounted Thread ANSI MNPT2, AlloyC, flush-mounted Thread ANSI MNPT2, 316L, flush-mounted Endress+Hauser...
  • Page 74: Pmp55 (Continued)

    SMS 1” PN25, 316L, EHEDG, 3A SMS 1-1/2” PN25, 316L, EHEDG, 3A SMS 2" PN25, 316L, EHEDG, 3A Special version Material of the process isolating diaphragm: 316L AlloyC Monel Tantalum Rhodium>gold>316L 0.09mm PTFE>316L, not for vacuum 0.25mm PTFE>316L, not for vacuum Special version Endress+Hauser...
  • Page 75: Pmp55 (Continued)

    Cable PE, 2m/80in + housing mounting bracket, wall/pipe, 304 Cable PE, 5m/200in + housing mounting bracket, wall/pipe, 304 Cable PE, 10m/400in + housing mounting bracket, wall/pipe, 304 Cable FEP, 5m/200in IP69K + housing mounting bracket, wall/pipe, 304 Add-on mounted: Overvoltage protection Endress+Hauser...
  • Page 76: Pmp55 (Continued)

    Welding fl. DRD DN50 65mm, 316L 3.1, EN10204-3.1 material, inspection certificate Weld-in tool flange DRD DN50 65mm, brass Plug-in jack M12 Plug-in jack M12, 90deg Plug-in jack M12, 90deg+5m cable Software version: 01.00.zz, HART, DevRev01 Identification: Measuring point (TAG) Bus address Endress+Hauser...
  • Page 77: Documentation

    – 4 to 20 mA HART – XA488P Ex ia IIIC Da/Db PMC51 – 4 to 20 mA HART – XA487P Ex ia IIC Ga/Gb PMC51, PMP51, PMP55 – 4 to 20 mA HART – XA473P Ex ia IIIC Da/Db Endress+Hauser...
  • Page 78: Installation/Control Drawings

    – 4 to 20 mA HART – ZD251P Zone 1,2 FM/CSA IS + XP Cl.I, II Div.1 Gr.A-D/B-G PMP55 FM IS/FM XP Cl.I, II Div.1 Gr.A-G+ – 4 to 20 mA HART – In preparation CSA IS/XP Cl.I, II Div.1 Gr.A-G, Zone 1,2 Endress+Hauser...
  • Page 79: Accessories

    C22.8 RA21 G1/2 316Ti RA22, BA22 100 (1500) NPT1/2 316Ti BB22 G1/2 C22.8 RC11 NPT1/2 C22.8 RD11 Max. operating temperature 120°C (248°F) in front of the siphon See also  ä 63 ff, feature 620, "Accessory enclosed", version "P4". Endress+Hauser...
  • Page 80: Welding Necks And Weld-In Tool Flanges

    QE / QF QJ / QK PMP55 QA / QB QJ / QK QP / QR Weld-in tool adapters Material brass PMC51 PMP51 PMP55  ä 19 ff Mounting bracket for wall and pipe mounting  ä 13 ff M12 connector Endress+Hauser...
  • Page 81: Configuration Data Sheet (Hart Electronics)

    [pres. eng. unit] [Scaled Unit] Example Display Information 1st Value Display 2nd Value Display 300 mbar Measured Value (PV) none (factory setting) Pressure Current [mA] Temperature Measured value (%) 0 mbar Damping Damping: ____ sec (Default 2 sec) P01-PMX5xxxx-16-xx-xx-en-000 Endress+Hauser...
  • Page 82: Pressure

    Upper range value (URV):_____________________ [pressure engineering unit) Display Information 1st Value Display 2nd Value display Main Value none (default) Pressure Current [mA] Temperature Measured value (%) Damping Damping: ____ sec (Default 2 sec) P01-xxxxxxxx-16-xx-xx-en-001 Note! Smallest span (factory calibration)  ä 7 ff. Endress+Hauser...
  • Page 83: Configuration Data Sheet (Analog Electronics)

    Upper range value (URV):_____________________ [pressure engineering unit) Display Information 1st Value Display 2nd Value display  Main Value none (default, not editable) Damping Damping: 2 sec ( default, not editable P01-xxxxxxxx-16-xx-xx-en-002 Note! Smallest span (factory calibration)  ä 7 ff. Endress+Hauser...
  • Page 84 Cerabar M PMC51, PMP51, PMP55 Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel. +41 61 715 81 00 Fax +41 61 715 25 00 www.endress.com info@ii.endress.com TI436P/00/EN/02.10 No. 71109889 CCS/FM+SGML 6.0 71109889...

This manual is also suitable for:

Cerabar m pmc51Cerabar m pmp55

Table of Contents